Counting Efficiencies Determined by Monte Carlo Methods for In Vivo Measurement of I-131 Activity in Thyroid

Authors
Park, MinSeokKwon, Tae-EunHa, Wi-HoKim, Chan HyeongPark, SunhooJin, Young Woo
Issue Date
Oct-2019
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
contamination; internal; counting efficiency; I-131; thyroid
Citation
HEALTH PHYSICS, v.117, no.4, pp.388 - 395
Indexed
SCIE
SCOPUS
Journal Title
HEALTH PHYSICS
Volume
117
Number
4
Start Page
388
End Page
395
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/12447
DOI
10.1097/HP.0000000000001070
ISSN
0017-9078
Abstract
The counting efficiencies obtained using a physical neck phantom are typically used in the measurement of I-131 activity in the thyroid. It is well known, however, that the geometrical discrepancies between the physical neck phantom and the anatomy of the subject can significantly influence the counting efficiencies. Thus, it is necessary to consider the anatomical characteristics of individuals if we need to accurately determine the activity of I-131 in the thyroid. This study aims to produce individualized counting efficiencies for thyroid measurement, considering the age, sex, and overlying tissue thickness of the subject being measured by Monte Carlo simulation. Simulations were performed using a series of computational human phantoms of different ages and sexes. The difference in counting efficiencies, depending on the age and sex of the phantom, were found to range from -26 to 3% for the phantoms and monitoring systems considered in the present study. The overlying tissue thickness of the computational phantoms was also modified to find the relationship between the counting ratio of the 80.2 and 364 keV gammas from I-131 and the overlying tissue thickness. The equations for estimating the overlying tissue thickness of a subject were then derived from the relationships between counting ratios and overlying tissue thickness. Finally, in the present study, a set of equations representing the variation in counting efficiencies for the 364 keV peak as a function of the overlying tissue thickness were derived, which can be used to determine individualized counting efficiencies for the subject being measured. These individualized counting efficiencies considering the overlying tissue thickness given a subject's age and sex can provide accurate estimates of I-131 activity for internal dosimetry.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE