Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

A study on dose conversion from a material to human body using mesh phantom for retrospective dosimetry

Authors
Kim, Min ChaeKim, HyoungtaekHan, HaeginLee, JungilLee, Seung KyuChang, InsuKim, Jang-LyulKim, Chan Hyeong
Issue Date
Jul-2019
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Thermoluminescence (TL); Optically stimulated luminescence (OSL); Display glass of a mobile phone; Mesh phantom; Retrospective dosimtery
Citation
RADIATION MEASUREMENTS, v.126, pp.1 - 5
Indexed
SCIE
SCOPUS
Journal Title
RADIATION MEASUREMENTS
Volume
126
Start Page
1
End Page
5
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/13368
DOI
10.1016/j.radmeas.2019.106126
ISSN
1350-4487
Abstract
In case of a radiation emergency, thermoluminescence (TL) and optically stimulated luminescence (OSL) measurements from materials in a mobile phone have been developed to enable classification of exposed individuals within a short period of time. A reconstructed dose from a mobile phone does not, however, correspond directly to a human body dose. Therefore, several studies were tried to convert a phone dose to a human body dose. Because of the difficulty in obtaining conversion factors experimentally, Monte Carlo simulations have been carried out using human phantoms for various accident situations. In recent years phantoms made of mesh have been developed to solve some problems in traditional voxel phantoms such as limited posture. In the present study, simulations using the GEANT4 computer code were performed to obtain conversion factors using mesh phantoms. The geometry of a mobile phone was designed, reflecting latest structures, and a display glass was selected as a dosimetric material due to its wide detection area with a high radiation sensitivity. Four different positions (chest, hip, thigh, and hand) of a mobile phone on the phantom were considered. In addition, six exposure conditions of anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), isotropic (ISO), and rotational (ROT) exposure geometries and three different postures of standing, kneeling, and squatting were selected to reflect actual working situations. Three commonly used radiation sources (Iridium-192, Cesium-137, and Cobalt-60) were applied.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE