Subject-Independent Functional Near-Infrared Spectroscopy-Based Brain-Computer Interfaces Based on Convolutional Neural Networksopen access
- Authors
- Kwon, Jinuk; Im, Chang-Hwan
- Issue Date
- Mar-2021
- Publisher
- Frontiers Media S.A.
- Keywords
- brain& #8211; computer interface; functional near-infrared spectroscopy; deep learning; convolutional neural network; binary communication
- Citation
- Frontiers in Human Neuroscience, v.15, pp.1 - 9
- Indexed
- SCIE
SCOPUS
- Journal Title
- Frontiers in Human Neuroscience
- Volume
- 15
- Start Page
- 1
- End Page
- 9
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/1364
- DOI
- 10.3389/fnhum.2021.646915
- ISSN
- 1662-5161
- Abstract
- Functional near-infrared spectroscopy (fNIRS) has attracted increasing attention in the field of brain-computer interfaces (BCIs) owing to their advantages such as non-invasiveness, user safety, affordability, and portability. However, fNIRS signals are highly subject-specific and have low test-retest reliability. Therefore, individual calibration sessions need to be employed before each use of fNIRS-based BCI to achieve a sufficiently high performance for practical BCI applications. In this study, we propose a novel deep convolutional neural network (CNN)-based approach for implementing a subject-independent fNIRS-based BCI. A total of 18 participants performed the fNIRS-based BCI experiments, where the main goal of the experiments was to distinguish a mental arithmetic task from an idle state task. Leave-one-subject-out cross-validation was employed to evaluate the average classification accuracy of the proposed subject-independent fNIRS-based BCI. As a result, the average classification accuracy of the proposed method was reported to be 71.20 +/- 8.74%, which was higher than the threshold accuracy for effective BCI communication (70%) as well as that obtained using conventional shrinkage linear discriminant analysis (65.74 +/- 7.68%). To achieve a classification accuracy comparable to that of the proposed subject-independent fNIRS-based BCI, 24 training trials (of approximately 12 min) were necessary for the traditional subject-dependent fNIRS-based BCI. It is expected that our CNN-based approach would reduce the necessity of long-term individual calibration sessions, thereby enhancing the practicality of fNIRS-based BCIs significantly.
- Files in This Item
-
- Appears in
Collections - ETC > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.