Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracyopen access

Authors
Park, Jun-YoungLee, YongguHeo, RanPark, Hyun-KyungCho, Seok-HyunCho, Sung HoLim, Young-Hyo
Issue Date
Dec-2021
Publisher
NATURE RESEARCH
Citation
SCIENTIFIC REPORTS, v.11, no.1, pp.1 - 12
Indexed
SCIE
SCOPUS
Journal Title
SCIENTIFIC REPORTS
Volume
11
Number
1
Start Page
1
End Page
12
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/138475
DOI
10.1038/s41598-021-03069-2
ISSN
2045-2322
Abstract
Recently, noncontact vital sign monitors have attracted attention because of issues related to the transmission of contagious diseases. We developed a real-time vital sign monitor using impulse-radio ultrawideband (IR-UWB) radar with embedded processors and software; we then evaluated its accuracy in measuring heart rate (HR) and respiratory rate (RR) and investigated the factors affecting the accuracy of the radar-based measurements. In 50 patients visiting a cardiology clinic, HR and RR were measured using IR-UWB radar simultaneously with electrocardiography and capnometry. All patients underwent HR and RR measurements in 2 postures—supine and sitting—for 2 min each. There was a high agreement between the RR measured using radar and capnometry (concordance correlation coefficient [CCC] 0.925 [0.919–0.926]; upper and lower limits of agreement [LOA], − 2.21 and 3.90 breaths/min). The HR measured using radar was also in close agreement with the value measured using electrocardiography (CCC 0.749 [0.738–0.760]; upper and lower LOA, − 12.78 and 15.04 beats/min). Linear mixed effect models showed that the sitting position and an HR < 70 bpm were associated with an increase in the absolute biases of the HR, whereas the sitting position and an RR < 18 breaths/min were associated with an increase in the absolute biases of the RR. The IR-UWB radar sensor with embedded processors and software can measure the RR and HR in real time with high precision. The sitting position and a low RR or HR were associated with the accuracy of RR and HR measurement, respectively, using IR-UWB radar.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 융합전자공학부 > 1. Journal Articles
서울 의과대학 > 서울 이비인후과학교실 > 1. Journal Articles
서울 의과대학 > 서울 소아청소년과학교실 > 1. Journal Articles
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Yong gu photo

Lee, Yong gu
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE