Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparisons of Videolaryngoscopes for Intubation Undergoing General Anesthesia: Systematic Review and Network Meta-Analysis of Randomized Controlled Trialsopen access

Authors
Lee, JuncheolCho, YoungsukKim, WonheeChoi, Kyu-SunJang, Bo-HyoungShin, HyungooAhn, ChiwonKim, Jae GukNa, Min KyunLim, Tae HoKim, Dong Won
Issue Date
Mar-2022
Publisher
MDPI
Keywords
laryngoscopes; anesthesia; intubation; systematic review; meta-analysis
Citation
JOURNAL OF PERSONALIZED MEDICINE, v.12, no.3, pp.1 - 29
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF PERSONALIZED MEDICINE
Volume
12
Number
3
Start Page
1
End Page
29
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/139295
DOI
10.3390/jpm12030363
Abstract
Background: The efficacy and safety of videolaryngoscopes (VLs) for tracheal intubation is still conflicting and changeable according to airway circumstances. This study aimed to compare the efficacy and safety of several VLs in patients undergoing general anesthesia. Methods: Medline, EMBASE, and the Cochrane Library were searched until 13 January 2020. The following VLs were evaluated compared to the Macintosh laryngoscope (MCL) by network meta-analysis for randomized controlled trials (RCTs): Airtraq, Airwayscope, C-MAC, C-MAC D-blade (CMD), GlideScope, King Vision, and McGrath. Outcome measures were the success and time (speed) of intubation, glottic view, and sore throat (safety). Results: A total of 9315 patients in 96 RCTs were included. The highest-ranked VLs for first-pass intubation success were CMD (90.6 % in all airway; 92.7% in difficult airway) and King Vision (92% in normal airway). In the rank analysis for secondary outcomes, the following VLs showed the highest efficacy or safety: Airtraq (safety), Airwayscope (speed and view), C-MAC (speed), CMD (safety), and McGrath (view). These VLs, except McGrath, were more effective or safer than MCL in moderate evidence level, whereas there was low certainty of evidence in the intercomparisons of VLs. Conclusions: CMD and King Vision could be relatively successful than MCL and other VLs for tracheal intubation under general anesthesia. The comparisons of intubation success between VLs and MCL showed moderate certainty of evidence level, whereas the intercomparisons of VLs showed low certainty evidence.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 마취통증의학교실 > 1. Journal Articles
서울 의과대학 > 서울 신경외과학교실 > 1. Journal Articles
서울 의과대학 > 서울 응급의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Tae Ho photo

Lim, Tae Ho
COLLEGE OF MEDICINE (DEPARTMENT OF EMERGENCY MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE