Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

인지부하의 정도에 따른 뇌신경생리학적 변화Changes in Electrophysiological Activation Due to Different Levels of Cognitive Load

Other Titles
Changes in Electrophysiological Activation Due to Different Levels of Cognitive Load
Authors
권주희김의진김정희임창환김도원
Issue Date
Feb-2022
Publisher
대한의용생체공학회
Keywords
Cognitive workload; n-back task; Electroencephalogram; Event-related potential; Event-related spectral perturbation; Source activity
Citation
의공학회지, v.43, no.1, pp.52 - 60
Indexed
KCI
Journal Title
의공학회지
Volume
43
Number
1
Start Page
52
End Page
60
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/139545
DOI
10.9718/JBER.2022.43.1.52
ISSN
1229-0807
Abstract
For now, cognitive load is assessed based on survey-based methods, which can be difficult to track the amount of cognitive load in real-time. In this study, we investigated the difference in electrophysiological activation due to different levels of cognitive load not only at sensor-level but also at source-level using electro- encephalogram that might be potentially used for quantitative cognitive load evaluation. Materials and Methods: In this study, ten healthy subjects (mean age 24.3 ± 2.1, three female) participated the experiment. All participants performed 4 sessions of n-back task in different difficulties: 0-, 1-, 2-, and 3-back during electroencephalogram record- ing. For sensor-level analysis, we calculated the event-related potential and event-related spectral perturbation while low resolution brain electromagnetic tomography (LORETA) to estimate the source activation. Each result was com- pared between different workload conditions using statistical analysis. Results: Statistical results revealed that the accuracy of the task performance was significantly different between different cognitive loads (p = 0.018). The post- hoc analysis confirmed that the accuracy of the 3-back task was significantly decreased compared to 1-back condition (p = 0.018), but not with 2-back condition (p = 0.180). ERP results showed that P300 target amplitude between 1- back and 3-back had a marginal difference in Cz (p = 0.059) and Pz(p = 0.093). A significant inhibition in Cz high-beta activation (p = 0.017) and decrease in source activation of right parahippocampal gyrus was found in 3-back condition compared to 1-back condition (p < 0.05). Conclusion: In this study, we compared the sensor- and source-level dif- ferences in electroencephalogram between different levels of cognitive load, that were found to be in line with the previous reports related to cognitive load evaluation. We expect that the outcome of the current study can be used as a feature to establish a quantitative cognitive load assessment system.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Im, Chang Hwan photo

Im, Chang Hwan
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE