Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

High-volume sampler for size-selective sampling of bioaerosols including virusesopen access

Authors
Lim, Jun-HyungNam, Sang-HwanKim, JongwooKim, Nam HoonPark, Gun-SooMaeng, Jin-SooYook, Se-Jin
Issue Date
Nov-2021
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Bioaerosol; Size-selective sampler; High-volume sampler; Cyclone separator; Filter
Citation
ATMOSPHERIC ENVIRONMENT, v.265, pp.1 - 8
Indexed
SCIE
SCOPUS
Journal Title
ATMOSPHERIC ENVIRONMENT
Volume
265
Start Page
1
End Page
8
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/140311
DOI
10.1016/j.atmosenv.2021.118720
ISSN
1352-2310
Abstract
Owing to the recent global spread of the new coronavirus SARS-CoV-2, the development of technology to effectively detect viruses in crowded public places is urgently needed. In this study, a three-stage high-volume bioaerosol sampler was developed for the size-selective sampling of bioaerosols through the suction of air at a high flow rate of 1000 L/min. In stage 1, an omnidirectional inlet cyclone separator that can draw air from all directions was applied to collect bioaerosols larger than 10 μm in the collection fluid. In stage 2, an axial flow cyclone separator was used to collect bioaerosols sized between 2.5 and 10 μm in the collection fluid. In stage 3, bioaerosols smaller than 2.5 μm were collected on a filter and extracted in a solution through an elution process using a sodium phosphate buffer. To simulate the suspension of bioparticles including viruses that are attached to other particles in the atmosphere, the aerosol samples were prepared by coagulating aerosolized bacteriophages with Arizona test dust. Then, the coagulated particles were collected for 30 min using the developed bioaerosol sampler, and the samples collected in each stage were analyzed via polymerase chain reaction (PCR) method. The PCR analysis results confirmed that the high-volume bioaerosol sampler enables size-selective bioaerosol sampling even at a high airflow rate of 1000 L/min. The developed high-volume bioaerosol sampler will be useful in detecting viruses through PCR analysis because it can collect bioaerosols within a specific size range.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yook, Se Jin photo

Yook, Se Jin
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE