Radiation Hardness Test of a Silicon Detector under Radiation Dose Rate of Nuclear Power Plant for In-Containment Coolant Leakage Detection Systemopen access
- Authors
- Kim, Jongheon; Pak, Kihong; Park, Junesic; Kim, Yong Kyun
- Issue Date
- Jun-2021
- Publisher
- EDP Sciences
- Keywords
- Silicon detector; Irradiation test; Coolant leakage detection system
- Citation
- EPJ Web of Conferences, v.253, pp 1 - 4
- Pages
- 4
- Indexed
- FOREIGN
- Journal Title
- EPJ Web of Conferences
- Volume
- 253
- Start Page
- 1
- End Page
- 4
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/141611
- DOI
- 10.1051/epjconf/202125305004
- ISSN
- 2100-014X
- Abstract
- An influence evaluation by background radiation on a silicon detector, which will be used to detect a coolant leakage, and installed in a containment building of a nuclear power plant, was performed and the result was discussed. The detector that consists of a silicon sensor and preamplifier mounted in a shielding structure which composed of a 5 cm lead cylinder will be installed in an annulus zone that is influenced by background radiation (neutron and gamma ray) from an operation of a nuclear reactor. Absorbed dose rates on a silicon sensor and preamplifier were calculated as 2.15 mGy/hr and 1.05 mGy/hr, respectively, by Monte Carlo N-Particle (MCNP) simulation. Data of background radiation had referred to a Final Safety Analysis Report (FSAR) of a nuclear power plant in the Republic of Korea. A silicon sensor and preamplifier were irradiated by a Co-60 gamma radiation source equipped in a facility of Korea Atomic Energy Research Institute Advanced Radiation Technology Institute (KAERI ARTI) of the Republic of Korea. A Po-210 alpha source was used as a check source to evaluate a state of a function of the detector during gamma irradiation. Absorbed dose rates were about 22.92 mGy/hr and 6.6 mGy/hr on silicon sensor and preamplifier, respectively. Before and during gamma irradiation, a count rates from the check source wasn't changed (from 18.4 cps to 18.4 +/- 0.2 cps after irradiation), and any degradations of function also weren't observed. Even more harsh condition than calculated dose rates referred by the condition of background radiation of in-containment, the silicon detector maintained the ability of function of charged particles detection. Based on the result, it has been demonstrated that a silicon detector is a suitable detector for detecting charged particles from a leaked coolant even during interfered by the background radiation of a primary system of a nuclear power plant.
- Files in This Item
-
- Appears in
Collections - 서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.