Detailed Information

Cited 2 time in webofscience Cited 1 time in scopus
Metadata Downloads

Feasibility study for simple on-line Raman spectroscopic detection of microplastic particles in water using perfluorocarbon as a particle-capturing medium

Authors
Cho, SanghoonKim, YunjungChung, Hoeil
Issue Date
Jun-2021
Publisher
ELSEVIER
Keywords
Microplastics; Perfluorohexane; On-line analysis; Wide area Raman measurement
Citation
ANALYTICA CHIMICA ACTA, v.1165, pp.1 - 7
Indexed
SCIE
SCOPUS
Journal Title
ANALYTICA CHIMICA ACTA
Volume
1165
Start Page
1
End Page
7
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/141836
DOI
10.1016/j.aca.2021.338518
ISSN
0003-2670
Abstract
A simple Raman spectroscopic scheme for on-line detection of microplastics (MPs) in water is demonstrated. Instead of using a conventional physical filter for MP separation, perfluorohexane (PFH, C6F14) was deployed as an MP-capturing medium in this study. When PFH was added into a water-filled L-shape tube, it formed a firm droplet at the bottom of the 90 degrees curve due to its strong hydrophobicity and high density. When a tap water sample containing dispersed polyethylene (PE) particles was flowed through the L-tube, the contained PFH droplet effectively captured the PE particles, with an average recovery of 95.9%. Next, for reliable quantitative analysis, it was necessary to measure the entire PE particle captured PFH droplet in Raman spectral acquisition without partial spectroscopic sampling. Therefore, a wide area illumination (WAI) scheme providing a laser illumination diameter of 6 mm was adopted for sampling of the whole droplet. The intensity ratios of PE and PFH peaks in the collected spectra clearly increased with elevated quantities of dispersed PE particles. When samples of PE particles were measured in sea water, which possesses much higher ionic strength than does tap water, the shapes of PE particle-captured PFH droplets did not change, and the accuracy was maintained. Based on these results, the demonstrated analytical scheme is feasible for field analysis; further study is required to strengthen its utility.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE