Cited 1 time in
Biomechanical evaluation of the stability of extra-articular distal radius fractures fixed with volar locking plates according to the length of the distal locking screw
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Oh, Gyung-Hwan | - |
| dc.contributor.author | Kim, Hak-Sung | - |
| dc.contributor.author | Lee, Jung Il | - |
| dc.date.accessioned | 2022-07-06T17:43:55Z | - |
| dc.date.available | 2022-07-06T17:43:55Z | - |
| dc.date.created | 2021-05-11 | - |
| dc.date.issued | 2021-06 | - |
| dc.identifier.issn | 1025-5842 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/141861 | - |
| dc.description.abstract | Surgeons usually used short screws to avoid extensor tendon problems during volar locking plate fixation in distal radius fracture. However, the stability according to the length of distal locking screws have not been fully understood. We investigated this issue through finite element analysis and compression test using synthetic radius. Our results demonstrated that the bi-cortical full-length fixation does not contribute to the stiffness increase in the axial compression direction, and a reduction in length of up to more than 50% length can still provide similar stability to full-length screws. Our data can support that surgeon should undersize the distal screw. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | TAYLOR & FRANCIS LTD | - |
| dc.title | Biomechanical evaluation of the stability of extra-articular distal radius fractures fixed with volar locking plates according to the length of the distal locking screw | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Kim, Hak-Sung | - |
| dc.identifier.doi | 10.1080/10255842.2020.1861254 | - |
| dc.identifier.scopusid | 2-s2.0-85097893086 | - |
| dc.identifier.wosid | 000600765900001 | - |
| dc.identifier.bibliographicCitation | COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, v.24, no.8, pp.922 - 932 | - |
| dc.relation.isPartOf | COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING | - |
| dc.citation.title | COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING | - |
| dc.citation.volume | 24 | - |
| dc.citation.number | 8 | - |
| dc.citation.startPage | 922 | - |
| dc.citation.endPage | 932 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.journalClass | 1 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Computer Science | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Computer Science, Interdisciplinary Applications | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
| dc.subject.keywordPlus | Compression testing | - |
| dc.subject.keywordPlus | Fracture | - |
| dc.subject.keywordPlus | Screws | - |
| dc.subject.keywordPlus | Biomechanical evaluation | - |
| dc.subject.keywordPlus | Compression directions | - |
| dc.subject.keywordPlus | Distal locking | - |
| dc.subject.keywordPlus | Distal radius fracture | - |
| dc.subject.keywordPlus | Plate fixation | - |
| dc.subject.keywordPlus | Stiffness increase | - |
| dc.subject.keywordPlus | Article | - |
| dc.subject.keywordPlus | biomechanics | - |
| dc.subject.keywordPlus | bone density | - |
| dc.subject.keywordPlus | bone microarchitecture | - |
| dc.subject.keywordPlus | cortical bone | - |
| dc.subject.keywordPlus | distal radius fracture | - |
| dc.subject.keywordPlus | dual energy X ray absorptiometry | - |
| dc.subject.keywordPlus | elemental analysis | - |
| dc.subject.keywordPlus | finite element analysis | - |
| dc.subject.keywordPlus | fluorometry | - |
| dc.subject.keywordPlus | ground reaction force | - |
| dc.subject.keywordPlus | human | - |
| dc.subject.keywordPlus | multidetector computed tomography | - |
| dc.subject.keywordPlus | osseointegration | - |
| dc.subject.keywordPlus | plate fixation | - |
| dc.subject.keywordPlus | radius shaft fracture | - |
| dc.subject.keywordPlus | surgeon | - |
| dc.subject.keywordPlus | trabecular bone | - |
| dc.subject.keywordPlus | volar plate fixation | - |
| dc.subject.keywordPlus | Young modulus | - |
| dc.subject.keywordPlus | biomechanics | - |
| dc.subject.keywordPlus | bone plate | - |
| dc.subject.keywordPlus | bone screw | - |
| dc.subject.keywordPlus | information processing | - |
| dc.subject.keywordPlus | mechanical stress | - |
| dc.subject.keywordPlus | osteosynthesis | - |
| dc.subject.keywordPlus | procedures | - |
| dc.subject.keywordPlus | radius fracture | - |
| dc.subject.keywordPlus | reconstructive surgery | - |
| dc.subject.keywordPlus | Locks (fasteners) | - |
| dc.subject.keywordAuthor | Distal radius fracture | - |
| dc.subject.keywordAuthor | biomechanical test | - |
| dc.subject.keywordAuthor | fine element analysis | - |
| dc.subject.keywordAuthor | volar locking plate | - |
| dc.subject.keywordAuthor | unicortical fixation | - |
| dc.subject.keywordAuthor | screw length | - |
| dc.identifier.url | https://www.tandfonline.com/doi/full/10.1080/10255842.2020.1861254 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
