Design Study of Steel Fibre Reinforced Concrete Shaft Lining for Swelling Ground in Toronto, Canadaopen access

Authors
Kim, Min SeongLee, Sean Seung won
Issue Date
Apr-2021
Publisher
MDPI
Keywords
shaft lining; steel fibre reinforced concrete; time-dependent deformation; finite element method
Citation
APPLIED SCIENCES-BASEL, v.11, no.8, pp.1 - 16
Indexed
SCIE
SCOPUS
Journal Title
APPLIED SCIENCES-BASEL
Volume
11
Number
8
Start Page
1
End Page
16
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/142112
DOI
10.3390/app11083490
ISSN
2076-3417
Abstract
Reinforced concrete (RC) is a widely used construction material around the world. RC has many advantages in terms of structural stability. However, the reinforcement of RC requires extensive labour costs. Steel fibre reinforced concrete (SFRC) has been widely studied to replace steel bars in concrete structures over the decades. However, most underground structures, such as tunnel lining, are usually designed using conventional RC for long-term stability due to unexpected geotechnical characteristics, such as directional and depth-dependent varied lateral pressure, earthquakes, groundwater, and time-dependent swelling behaviour. In this paper, an alternative design of shaft structure using SFRC, based on the original RC designed data in the Toronto region, was studied to evaluate the feasibility of SFRC replacing conventional RC. A key geological feature of the site is that the bedrock is comprised of Georgian Bay shale, which exhibits long-term time-dependent deformation (TDD). The capacities of RC and SFRC for the shaft lining were calculated based on the Canadian concrete design codes CSA A23.3 and RILEM TC 162-TDF, to assess the benefit of adding steel fibre, and several analytical solutions were used to calculate the applied load on the lining. A specialised TDD constitutive model in Fast Lagrangian Analysis of Continua (FLAC) 2D was developed to estimate whether the optimum installation time of the shaft lining, based on the geological reports, is appropriate under swelling behaviour, and evaluate the resultant long-term stability. The calculated hoop thrust and bending moment for several loading cases were within the capacity of the SFRC shaft lining. The numerical analysis demonstrated that the proposed lining installation time could be reduced, despite consideration of the long-term TDD behaviour.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 자원환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sean Seung won photo

Lee, Sean Seung won
COLLEGE OF ENGINEERING (DEPARTMENT OF EARTH RESOURCES AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE