Detailed Information

Cited 7 time in webofscience Cited 9 time in scopus
Metadata Downloads

Energy saving potential of a vacuum-based membrane dehumidifier in a dedicated outdoor air system

Authors
Cheon, Seong-YongCho, Hye-JinJeong, Jae-Weon
Issue Date
Jan-2021
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Vacuum-based membrane dehumidifier; Dedicated outdoor air system; Isothermal dehumidification; Ventilation; Energy simulation
Citation
ENERGY CONVERSION AND MANAGEMENT, v.227
Indexed
SCIE
SCOPUS
Journal Title
ENERGY CONVERSION AND MANAGEMENT
Volume
227
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/142536
DOI
10.1016/j.enconman.2020.113618
ISSN
0196-8904
Abstract
As a novel energy-conservative ventilation system for buildings, a dedicated outdoor air system (DOAS) assisted by a vacuum-based membrane dehumidifier is proposed, and its energy performance is investigated via detailed energy simulations. The vacuum-based membrane dehumidifier dries the air by an isothermal process, which is difficult to realize in conventional dehumidification systems. The proposed system consists of an enthalpy exchanger, a vacuum-based membrane dehumidifier, and a cooling coil. Its dehumidification performance and operation energy are compared with those of the following conventional DOASs: a DOAS that employs a cooling coil (Reference A) and a DOAS that employs an active desiccant wheel (Reference B). To evaluate the energy performance of the proposed system, the energy consumptions of all the DOASs were estimated by simulation programs (i.e., TRNSYS and EES) with mathematical models. The simulation results indicate that the average coefficient of performance of the DOAS we devised (i.e., 1.34) is lower than that of Reference A (i.e., 2.70) and higher than that of Reference B (i.e., 0.80). However, owing to the isothermal dehumidification process, the latent cooling ratio in the case of the proposed system (i.e., 1.0) is significantly higher than those in the cases of Reference A (i.e., 0.43) and Reference B (i.e., 0.11). Consequently, the annual energy consumption of the proposed system is 17.4% and 56.2% lower than those of Reference A and Reference B, respectively.
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE