Quantification of Displacement for Tactile Sensation in a Contact-type Low Intensity Focused Ultrasound Haptic Device

Authors
Choi, JeongbongYook, SoonhyunKim, In YoungJeong, Mok KunJang, Dong Pyo
Issue Date
Jan-2021
Publisher
ASSOC COMPUTING MACHINERY
Keywords
Tactile threshold; displacement; low intensity focused ultrasound
Citation
ACM TRANSACTIONS ON APPLIED PERCEPTION, v.18, no.1, pp.1 - 8
Indexed
SCIE
SCOPUS
Journal Title
ACM TRANSACTIONS ON APPLIED PERCEPTION
Volume
18
Number
1
Start Page
1
End Page
8
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/142552
DOI
10.1145/3422820
ISSN
1544-3558
Abstract
Tactile threshold of low-intensity focused ultrasound (LIFU) haptic devices has been defined as the minimum pressure required for tactile sensation. However, in contact-type LIFU haptic devices using an elastomer as a conductive medium, the tactile threshold is affected by the mechanical properties of the elastomer. Therefore, the tactile threshold needs to be redefined as a parameter that does not change with the mechanical properties of the elastomer. In this study, we used the LIFU haptic device to investigate the displacement of the elastomer surface at the tactile threshold while controlling the pulse duration, pulse repetition frequency, and pressure. We analyzed the displacement magnitude and rate to determine their relationship to the pressure. The displacement magnitude is the spatiotemporal peak of the displacement, and the displacement rate is the initial slope of the displacement at the starting point of LIFU pulse. The tactile threshold measured by the applied pressure showed the U-shaped graph, and the minimum pressure of 475 kPa at 2 ms and 407 kPa at 300 Hz was measured. The tactile threshold measured by the displacement show that the tactile sensation can be evoked at the small displacement magnitude (<3 mu m) when the high displacement rate is present (>1.56 mm/s). Furthermore, the large displacement magnitude is required to induce the tactile sensation when the displacement rate is low. This result shows that the tactile threshold of a contact-type LIFU haptic device is affected by both the displacement magnitude and rate of the conductive medium. Our findings can be used as a guideline for developing a contact-type LIFU haptic device regardless of the elastomer used.
Files in This Item
Go to Link
Appears in
Collections
서울 의생명공학전문대학원 > 서울 의생명공학전문대학원 > 1. Journal Articles
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Dong Pyo photo

Jang, Dong Pyo
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING (서울 생체의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE