Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Feasibility Study of a Small Field Detector Based on a Microfluidic Calorimeter

Full metadata record
DC Field Value Language
dc.contributor.authorSchaarschmidt, Thomas-
dc.contributor.authorKim, Yong Kyun-
dc.contributor.authorChung, Hyun-Tai-
dc.date.accessioned2021-08-02T11:53:42Z-
dc.date.available2021-08-02T11:53:42Z-
dc.date.created2021-05-12-
dc.date.issued2019-04-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/14264-
dc.description.abstractThe widespread proliferation of modern external beam radiotherapy devices employing small or non-standard fields has created a number of challenges for accurate reference dosimetry measurements based on ionization chambers, as they require an ever increasing number of corrections. A miniature water-based calorimeter, on the other hand, would allow for direct measurement of absorbed dose to water that can be traced to standards entirely independent of radiation. In this study, a microfluidic calorimeter prototype developed at the Korea Advanced Institute of Science and Technology was assessed for its feasibility as a detector for measurement of absolute dose to water in small and composite fields. Using the GEANT4 Monte Carlo simulation toolkit, the detector design was examined for the water equivalence and the angular dependence of the absorbed dose to the active calorimeter volume inside three different radiation fields. The initial design exhibited poor water equivalence but this was remedied through a simple modification to the detector geometry. The modified design was subsequently re-tested and it showed a maximum water equivalence deviation of 1.15% while angular fluctuations remained within 1.1%, thus indicating that the modified microfluidic calorimeter is a promising concept for the construction of a calorimeter-based absorbed dose to water detector for absolute dosimetry.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.titleFeasibility Study of a Small Field Detector Based on a Microfluidic Calorimeter-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Yong Kyun-
dc.identifier.doi10.3938/jkps.74.630-
dc.identifier.scopusid2-s2.0-85064461034-
dc.identifier.wosid000466727600001-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.74, no.7, pp.630 - 636-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume74-
dc.citation.number7-
dc.citation.startPage630-
dc.citation.endPage636-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002456447-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusSIMULATION-
dc.subject.keywordAuthorMicrofluidic calorimeter-
dc.subject.keywordAuthorSmall field dosimetry-
dc.subject.keywordAuthorAbsorbed dose-
dc.subject.keywordAuthorAbsolute measurement-
dc.subject.keywordAuthorHigh-precision radiotherapy-
dc.subject.keywordAuthorMonte Carlo simulation-
dc.identifier.urlhttps://link.springer.com/article/10.3938/jkps.74.630-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Kyun photo

Kim, Yong Kyun
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE