Detailed Information

Cited 4 time in webofscience Cited 4 time in scopus
Metadata Downloads

Influence of interfering co-appearing container peaks on the accuracy of direct quantitative Raman measurement of a sample in a plastic container

Authors
Lee, YoonjeongPham Khac DuySriphong, LawanKaewnopparat, NatthaChung, Hoeil
Issue Date
Aug-2020
Publisher
ROYAL SOC CHEMISTRY
Citation
ANALYST, v.145, no.16, pp.5539 - 5546
Indexed
SCIE
SCOPUS
Journal Title
ANALYST
Volume
145
Number
16
Start Page
5539
End Page
5546
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/145328
DOI
10.1039/d0an00741b
ISSN
0003-2654
Abstract
The axially perpendicular offset (APO) scheme was previously demonstrated as a versatile scheme able to minimize or eliminate the glass background in the direct and non-sampling Raman measurement of an ethanol sample housed in a glass bottle. Alternatively, when directly analyzing a sample housed in a plastic container, another typical container yielding strong Raman peaks itself, the Raman peaks of both the container and the housed sample are unavoidably present together in a collected spectrum. Therefore, a crucial issue to investigate under this situation is how the magnitude of the co-appearing container peaks influences the accuracy for quantitative analysis of the housed sample. For the evaluation, a non-sampling Raman spectroscopic measurement of the urea concentration in a urea gel housed in a circular polypropylene (PP) container was attempted by employing two axially perpendicular offset (APO) schemes with detection windows of different sizes (25.4 and 10.0 mm, referred to as the wide-window APO (WW-APO) and narrow-window APO (NW-APO), respectively), and transmission and back-scattering schemes incorporating a 25.4 mm detection window. The intensity ratios between the container and urea peaks in the collected spectra were different depending on the adopted measurement scheme. The intensity ratio was greatest (smallest container peak) in the NW-APO measurement due to the narrowed detection window, making the generated container Raman photons at the side-wall less detectable to the bottom-positioned detector. A spectral acquisition scheme allowing the maximal suppression of the container peaks, while still maintaining the sample features, was a key requirement to secure an accurate measurement of the sample concentration. In addition, a Monte Carlo simulation was used to visualize the distributions of the container and urea photons inside the sample-housed container.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics