Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Computed Tomography (CT) Protocols Associated with Cardiac and Bone Single-Photon Emission Computed Tomography/CT (SPECT/CT) in Korea

Authors
Lee, Eun JeongKim, Ji YoungPark, Jung MiSong, Bong-IlChoi, HongyoonShim, Hye-kyeongPark, Hey LimLee, Ho-YoungLees, Kyung JaeYoon, Joon-KeeSeo, SeonghoKim, Seong MinPark, Soo BinCho, Young SeokKim, Seong Hoon
Issue Date
Jun-2020
Publisher
SPRINGER HEIDELBERG
Keywords
SPECT; CT; CT protocols; Optimization
Citation
NUCLEAR MEDICINE AND MOLECULAR IMAGING, v.54, no.3, pp.139 - 146
Indexed
SCOPUS
KCI
Journal Title
NUCLEAR MEDICINE AND MOLECULAR IMAGING
Volume
54
Number
3
Start Page
139
End Page
146
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/145649
DOI
10.1007/s13139-020-00644-9
ISSN
1869-3474
Abstract
Purpose Single-photon emission computed tomography/computed tomography (SPECT/CT) is an advanced hybrid nuclear medicine technology that generates both functional and anatomical images in a single study. As utilization of SPECT/CT in Korea has been increasing, the purpose of this study was to survey its application of cardiac and skeletal SPECT/CT imaging for protocol optimization. Methods We surveyed CT protocols established for cardiac and skeletal SPECT/CT. We searched the guidelines for the CT protocols for SPECT/CT and reviewed the literature recently published. Results Among 36 hybrid SPECT scanners equipped with four or more multi-channel detector CTs (MDCTs), 18 scanners were used to perform cardiac studies at both very low current CT (30–80 mA; 11.1%) and ultra-low current CT (13–30 mA; 88.9%). Among the 33 canners, very low current (≤ 80 mA) CT or low current CT (80–130 mA) was used in 23.5%, and 41.8% for spine disorders, and in 36.4% or 30.3% for foot/ankle disorders, respectively. In the CT reconstructions, slice thickness of 5 mm for cardiac studies was most commonly used (94.4%); thinner slices (0.6–1.0 mm) for spine and foot/ankle studies were used in 24.2% and 45.5%, respectively. We also reviewed the international guidelines. Conclusions The results and current recommendations will be helpful for optimizing CT protocols for SPECT/CT. Optimization of SPECT/CT protocols will be required for generating the proper strategy for the specific lesions and clinical purpose.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 핵의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Young photo

Kim, Ji Young
COLLEGE OF MEDICINE (DEPARTMENT OF NUCLEAR MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE