Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Implantable Cardioverter Defibrillator Shocks and Psychological Distress Examining the Mediating Roles of Implantable Cardioverter Defibrillator-Related Concerns and Perceived Control

Authors
Lee, Kyoung SukKim, Jun HyungKang, Ki-WoonMiller, JenniferMcEvedy, Samantha M.Hwang, Seon YoungMoser, Debra K.
Issue Date
Jan-2020
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
implantable cardioverter defibrillator; anxiety; depressive symptoms; perceived control
Citation
JOURNAL OF CARDIOVASCULAR NURSING, v.35, no.1, pp.66 - 73
Indexed
SCIE
SSCI
SCOPUS
Journal Title
JOURNAL OF CARDIOVASCULAR NURSING
Volume
35
Number
1
Start Page
66
End Page
73
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/146357
DOI
10.1097/JCN.0000000000000610
ISSN
0889-4655
Abstract
Background: Although the implantable cardioverter defibrillator (ICD) has a survival benefit for the prevention of sudden cardiac death, ICD recipients commonly experience emotional distress as a consequence of ICD shocks. Objective: The aim of this study was to examine whether the association between ICD shocks and psychological distress (anxiety and depressive symptoms) is mediated by ICD-related concerns and perceived control among ICD recipients. Methods: This was a multinational cross-sectional observational study of 334 ICD recipients. Patients reported the number of shocks received since ICD implantation and completed questionnaires to assess anxiety, depressive symptoms, ICD-related concerns, and perceived control. A path analysis was conducted to explore the relationship of receiving ICD shocks with anxiety and depressive symptoms and the mediating effects of ICD-related concerns and perceived control. Results: Of the 334 ICD recipients, 39.2% experienced ICD shocks at least once since implantation. There was no direct effect of ICD shocks on anxiety and depressive symptoms. Experiencing ICD shocks was indirectly associated with an increased likelihood of anxiety and depressive symptoms via the pathways of ICD-related concerns and perceived control (indirect effects on anxiety = 0.060, 0.043; indirect effect on depressive symptoms = 0.025, 0.073). Conclusion: Experiencing defibrillator shocks was associated with psychological distress in ICD recipients; the relationship was fully mediated by ICD-related concerns and perceived control. These results suggest that clinicians should routinely assess ICD-related concerns and perceived control in patients with ICD. Research is needed to develop and test interventions to decrease emotional distress related to the ICD shock experience.
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 간호학부 > 서울 간호학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hwang, Seon Young photo

Hwang, Seon Young
서울 간호대학 (서울 간호학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE