Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Signal-to-cutoff ratios of current anti-HCV assays and a suggestion of new algorithm of supplementary testing

Authors
Ha, JihyePark, YounheeKim, Hyon-Suk
Issue Date
Nov-2019
Publisher
ELSEVIER SCIENCE BV
Keywords
Anti-HCV assays; Hepatitis C virus; Immunoassay; Signal-to-cutoff ratio
Citation
CLINICA CHIMICA ACTA, v.498, pp.11 - 15
Indexed
SCIE
SCOPUS
Journal Title
CLINICA CHIMICA ACTA
Volume
498
Start Page
11
End Page
15
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/146776
DOI
10.1016/j.cca.2019.08.002
ISSN
0009-8981
Abstract
Background The detection of hepatitis C virus antibody (anti-HCV) is known to have high false-positive rates. Using signal-to-cutoff (S/Co) ratios in reflex supplemental testing, however, could reduce false-positive rates. Here, we analyzed the 2-year data of an anti-HCV assay to understand the significance of the S/Co ratio and make a new algorithm by confirming with a second anti-HCV assay. Methods We reviewed 32,573 samples of the Architect assay (Abbott Diagnostics) from a tertiary hospital. Retests with the Elecsys (Roche Diagnostics) and Vitros (Ortho Clinical Diagnostics) assays were performed in 346 anti-HCV-positive samples. HCV RNA PCR and recombinant immunoblot assay (RIBA) were performed in 147 and 11 anti-HCV-positive samples, respectively. Results Among 32,573 samples, 446 (1.37%) yielded positive results and 32,127 (98.6%) yielded negative results. Concordance rates in low S/Co samples (0.9–10.0) were 35.2%, 43.8%, and 81.9% for the Architect-Elecsys, Architect-Vitros, and Elecsys-Vitros comparisons, respectively. Correlation coefficients of S/Co ratios were as follows: Architect-Elecsys, 0.20; Architect-Vitros, 0.42; and Elecsys-Vitros, 0.46. In logistic regression, the S/Co value for predicting positivity with 95% probability was 3.13, while that for predicting 50% probability was 8.85. S/Co ratios of 1.70–3.34 showed one reactive antigen out of five antigens, and S/Co ratios of 13.54–17.72 showed three to five positive reactions out of five antigens used in the RIBA. Conclusions Supplementary testing of anti-HCV screening results is necessary to distinguish between true positivity and biological false positivity for anti-HCV. In this study, we presented an algorithm of supplementary testing by a retest with a second reagent, which could be useful in clinical laboratories.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 진단검사의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ha, Ji hye photo

Ha, Ji hye
COLLEGE OF MEDICINE (DEPARTMENT OF LABORATORY MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE