Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Factors influencing long-term survival rates of implants placed simultaneously with lateral maxillary sinus floor augmentation: A 6-to 20-year retrospective study

Authors
Park, Won-BaeKang, Kyung LhiHan, Ji-Young
Issue Date
Oct-2019
Publisher
WILEY
Keywords
bone regeneration; bone substitutes; guided tissue regeneration; sinus floor elevation; smoking
Citation
CLINICAL ORAL IMPLANTS RESEARCH, v.30, no.10, pp.977 - 988
Indexed
SCIE
SCOPUS
Journal Title
CLINICAL ORAL IMPLANTS RESEARCH
Volume
30
Number
10
Start Page
977
End Page
988
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/147009
DOI
10.1111/clr.13505
ISSN
0905-7161
Abstract
Objectives To evaluate the long-term influence of residual bone height (RBH), sinus membrane perforation and the presence of voids on the survival of implants placed simultaneously with lateral maxillary sinus floor augmentation (MSFA). Materials and Methods A total of 207 patients (613 implants) who underwent MSFA from 1999 to 2003 and followed up until 2018 were included in this study. RBH and marginal bone loss were assessed using a series of panoramic and periapical radiographs. Cumulative survival rates (CSR) with log-rank tests and hazard ratios of implant failure according to RBH, membrane perforation, and the presence of voids were assessed. Results The overall 10-year and 20-year CSRs were 95% (95% CI: 84.95%-85.05%) and 85% (95% CI: 84.95%-85.05%), respectively. CSR was significantly higher for implants with >= 3 mm RBH (n = 260, 92.4%) than those with <3 mm RBH (n = 353, 78.8%) (p = .002). CSR of non-smoking group (n = 312, 90.0%) was higher than that of smoking group (n = 301, 77.1%) (p = .009). There was no significant difference in the hazard ratio of implant failure between the perforated membrane group (n = 245) and the non-perforated group (n = 368). In two out of 11 patients with voids, the inflammation of peri-implantitis progressed into voids, resulting in severe bone resorption. Conclusions The survival of implants placed in <3 mm of RBH, even though it showed a lower CSR, could be considered acceptable. Neither sinus membrane perforation nor the presence of voids appeared to affect implant survival as long as supportive maintenance therapy with proper oral hygiene was provided.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 치과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Ji Young photo

Han, Ji Young
서울 의과대학 (DEPARTMENT OF DENTISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE