Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Diagnostic value of ganglion cell-inner plexiform layer for early detection of ethambutol-induced optic neuropathy

Authors
Lee, Ju YeunHan, JinuSeo, Jeong GiPark, Kyung-AhOh, Sei Yeul
Issue Date
Mar-2019
Publisher
BMJ PUBLISHING GROUP
Citation
BRITISH JOURNAL OF OPHTHALMOLOGY, v.103, no.3, pp.379 - 384
Indexed
SCIE
SCOPUS
Journal Title
BRITISH JOURNAL OF OPHTHALMOLOGY
Volume
103
Number
3
Start Page
379
End Page
384
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/148127
DOI
10.1136/bjophthalmol-2018-312063
ISSN
0007-1161
Abstract
Aim To evaluate the diagnostic value of macular ganglion cell-inner plexiform layer (mGCIPL) thickness versus peripapillary retinal nerve fibre layer (pRNFL) thickness for the early detection of ethambutol-induced optic neuropathy (EON). Methods Twenty-eight eyes of 15 patients in the EON group and 100 eyes of 53 healthy subjects in the control group were included. All patients with EON demonstrated the onset of visual symptoms within 3 weeks. Diagnostic power for pRNFL and mGCIPL thicknesses measured by Cirrus spectral-domain optical coherence tomography was assessed by area under the receiver operating characteristic (AUROC) curves and sensitivity. Results All of the mGCIPL thickness measurements were thinner in the EON group than in the control group in early EON (p<0.001). All of pRNFL thicknesses except inferior RNFL showed AUROC curves above 0.5, and all of the mGCIPL thicknesses showed AUROC curves above 0.5. The AUROC of the average mGCIPL (0.812) thickness was significantly greater than that of the average pRNFL (0.507) thickness (p<0.001). Of all the mGCIPL-related parameters considered, the minimum thickness showed the greatest AUROC value (0.863). The average mGCIPL thickness showed a weak correlation with visual field pattern standard deviations (r2=0.158, p<0.001). Conclusions In challenging cases of EON, the mGCIPL thickness has better diagnostic performance in detecting early-onset EON as compared with using pRNFL thickness. Among the early detection ability of mGCIPL thickness, minimum GCIPL thickness has high diagnostic ability.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 교육협력지원교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Ju Yeun photo

Lee, Ju Yeun
COLLEGE OF MEDICINE (DEPARTMENT OF MEDICAL COOPERATION)
Read more

Altmetrics

Total Views & Downloads

BROWSE