Airflow as a Possible Transmission Route of Middle East Respiratory Syndrome at an Initial Outbreak Hospital in Koreaopen access

Authors
Sung, MinkiJo, SeongminLee, Sang-EunKi, MoranChoi, Bo YoulHong, JinKwan
Issue Date
Dec-2018
Publisher
MDPI
Keywords
Middle East Respiratory Syndrome; infection outbreak; airflow analysis; transmission route; ventilation; tracer gas
Citation
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, v.15, no.12, pp.1 - 11
Indexed
SCIE
SSCI
SCOPUS
Journal Title
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH
Volume
15
Number
12
Start Page
1
End Page
11
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/148878
DOI
10.3390/ijerph15122757
ISSN
1661-7827
Abstract
In this study, the results of an airflow investigation conducted on 7 June 2015 as part of a series of epidemiologic investigations at Pyeongtaek St. Mary's Hospital, South Korea, were investigated. The study involved 38 individuals who were infected directly and indirectly with Middle East Respiratory Syndrome (MERS), by a super-spreader patient. Tracer gas experiments conducted on the eighth floor, where the initial patient was hospitalized, confirmed that the tracer gas spread to adjacent patient rooms and rooms across corridors. In particular, the experiment with an external wind direction and speed similar to those during the hospitalization of the initial patient revealed that the air change rate was 17-20 air changes per hour (ACH), with air introduced through the window in the room of the infected patient (room 8104). The tracer gas concentration of room 8110, which was the farthest room, was 7.56% of room 8104, indicating that a high concentration of gas has spread from room 8104 to rooms across the corridor. In contrast, the tracer gas was barely detected in a maternity ward to the south of room 8104, where there was no secondary infected patient. Moreover, MERS is known to spread mainly by droplets through close contact, but long-distance dispersion is probable in certain environments, such as that of a super-spreader patient hospitalized in a room without ventilation, hospitals with a central corridor type, and indoor airflow dispersion due to external wind.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 예방의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Bo Youl photo

Choi, Bo Youl
COLLEGE OF MEDICINE (DEPARTMENT OF PREVENTIVE MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE