Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Diagnostic Performance of Core Needle Biopsy and Fine Needle Aspiration Separately or Together in the Diagnosis of Intrathoracic Lesions Under C-arm Guidanceopen access

Authors
Lee, YoukyungPark, Choong-KiOh, Young Ha
Issue Date
Dec-2018
Publisher
UBIQUITY PRESS LTD
Keywords
Lung biopsy; Fine needle aspiration; Core needle biopsy; C-arm cone-beam CT system
Citation
JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, v.102, no.1, pp.1 - 9
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY
Volume
102
Number
1
Start Page
1
End Page
9
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/148913
DOI
10.5334/jbsr.1615
ISSN
2514-8281
Abstract
Purpose: To evaluate and compare the diagnostic accuracy of fine needle aspiration (FNA) and core needle biopsy (CNB) of intrathoracic lesions using the same coaxial guide-needle under a C-arm Cone-Beam computed tomography system. Materials and Methods: Two hundred and eighty-eight patients (181 male, 107 female; 65.8 ± 13.3 years) with 293 lesions underwent 300 procedures, in which both FNA and CNB were performed. After inserting the coaxial guide-needle into the target lesion, we performed 18-gauge CNB, followed by 20-gauge FNA through the same coaxial guide-needle. The comparison of the procedures in which both showed adequate sample was performed with McNemar’s test (n = 229). Results: Of 300 procedures, 293 were technically successful. Adequate samples were obtained in 248/300 FNA and 288/300 CNB cases. The sensitivity and specificity for diagnosis of malignancy were respectively 84.7% (133/157), 100% (72/72) for FNA, when atypical cells included benign entity; 97.5% (153/157), 100% (72/72) for FNA, when atypical cells included malignancy; 97.6% (162/166), 100% (102/102) for CNB; and 100% (166/166), 100% (102/102) for combined FNA and CNB. Diagnosis of malignancy was significantly higher for CNB than for FNA (p < 0.001); however, it was not significantly higher when atypical cells included malignancy for FNA. Pneumothorax occurred in 50 (16.7%) and hemoptysis in 18 (6.0%) procedures. Conclusions: Combined use of CNB and FNA using the same coaxial guide-needle showed better diagnostic performance than using one alone. When comparing CNB and FNA, CNB showed significantly better performance, when atypical cells included a benign entity in FNA.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 병리학교실 > 1. Journal Articles
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youkyung photo

Lee, Youkyung
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE