Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Three dimensional neuro-retinal rim thickness and retinal nerve fiber layer thickness using high-definition optical coherence tomography for open-angle glaucoma

Authors
Subramaniam, SureshJeoung, Jin WookLee, Won JuneKim, Young KookPark, Ki Ho
Issue Date
Nov-2018
Publisher
SPRINGER JAPAN KK
Keywords
End point of Bruch`s membrane; High-definition optical coherence tomography; Three-dimensional neuro-retinal rim thickness mapping; Unilateral open-angle glaucoma; Vitreo-retinal interface
Citation
JAPANESE JOURNAL OF OPHTHALMOLOGY, v.62, no.6, pp.634 - 642
Indexed
SCIE
SCOPUS
Journal Title
JAPANESE JOURNAL OF OPHTHALMOLOGY
Volume
62
Number
6
Start Page
634
End Page
642
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/148943
DOI
10.1007/s10384-018-0620-7
ISSN
0021-5155
Abstract
Purpose: To compare the diagnostic capability of three-dimensional (3D) neuro-retinal rim thickness (NRR) with existing optic nerve head and retinal nerve fiber layer (RNFL) scan parameters using high-definition optical coherence tomography (HD-OCT). Design: Retrospective study. Methods: Based on the mean deviation (MD) of the Humphrey Field Analyzer (HFA), the 152 subjects were categorized into mild (MD > - 6 dB, 100), moderate (MD - 6 to - 12 dB, 26), and severe (MD < - 12 dB, 26) glaucoma. The HD-OCT values of NRR, RNFL and ganglion cell inner plexiform layer (GCIPL) thicknesses, along with those of other parameters (rim area, disc area) were obtained, and the average NRR thickness was calculated. Results: For all of the HD-OCT parameters, RNFL thickness showed a higher area under the ROC (AUROC) curve (range: 0.937-1.000) than did NRR thickness (range: 0.827-1.000). There were significant RNFL, NRR, and GCIPL AUROC curve differences among the mild, moderate and severe glaucoma groups. RNFL thickness for mild glaucoma showed a significantly larger area than did NRR thickness [area difference: 0.110 (± 0.025); p value < 0.0001). Furthermore, RNFL relative to NRR thickness yielded higher sensitivity (85-100% vs. 72-100%) and specificity (89-100% vs. 84-100%) for diagnosis of glaucoma. Conclusion: RNFL thickness remains significantly better than 3D NRR thickness in terms of glaucoma-diagnostic capability in HD-OCT.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 안과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won June photo

Lee, Won June
COLLEGE OF MEDICINE (DEPARTMENT OF OPHTHALMOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE