멤브레인 제습장치를 이용한 외기전담시스템의 에너지 소비 및 성능 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 천성용 | - |
dc.contributor.author | 조혜진 | - |
dc.contributor.author | 윤수열 | - |
dc.contributor.author | 정재원 | - |
dc.date.accessioned | 2022-07-10T22:55:41Z | - |
dc.date.available | 2022-07-10T22:55:41Z | - |
dc.date.created | 2021-05-14 | - |
dc.date.issued | 2018-11 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/148950 | - |
dc.description.abstract | In this research, we proposed a dedicated outdoor air system (DOAS), which is integrated with a vacuum-based membrane dehumidifier (VMD). The main objective of this study is to evaluate the energy saving potential of VMD-DOAS, which is DOAS integrated with VMD. The proposed system is composed of a membrane energy exchanger (MEE), a dew point indirect evaporative cooler (DP-IEC), and VMD. The VMD has a characteristic that the dehumidification process conducts as an isothermal process, which is that the temperature change did not occur in the VMD. After the dry air is controlled by VMD, the DP-IEC operates to meet the target temperature (i.e., 17°C). The remaining sensible heat of the conditioned zone is deal with ceiling radiant cooling panel (CRCP). A load of condition zone was driven by TRANSYS 18 and engineering equation solver (EES) was used for evaluating the energy saving potential of the proposed system with CRCP comparing with variable air volume system. The results showed that the proposed DOAS with CRCP consumed 38% less operating energy consumption compared with the VAV system. The main energy saving potential of the proposed system was driven by reducing the dehumidification load and energy recovering by MEE. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | (사)한국건축친환경설비학회 | - |
dc.title | 멤브레인 제습장치를 이용한 외기전담시스템의 에너지 소비 및 성능 분석 | - |
dc.title.alternative | Energy Saving Potential of a Dedicated Outdoor Air System Assisted by Vacuum Based Membrane | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 정재원 | - |
dc.identifier.bibliographicCitation | 한국건축친환경설비학회 추계학술발표대회 논문집, pp.105 - 106 | - |
dc.relation.isPartOf | 한국건축친환경설비학회 추계학술발표대회 논문집 | - |
dc.citation.title | 한국건축친환경설비학회 추계학술발표대회 논문집 | - |
dc.citation.startPage | 105 | - |
dc.citation.endPage | 106 | - |
dc.type.rims | ART | - |
dc.type.docType | Proceeding | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | 외기전담시스템 | - |
dc.subject.keywordAuthor | 진공멤브레인 제습장치 | - |
dc.subject.keywordAuthor | 에너지 시뮬레이션 | - |
dc.subject.keywordAuthor | DOAS | - |
dc.subject.keywordAuthor | Vacuum based membrane dehumidifier | - |
dc.subject.keywordAuthor | Energy simulation | - |
dc.identifier.url | https://www.auric.or.kr/User/Rdoc/DocRdoc.aspx?returnVal=RD_R&dn=380425#.YSWgg99t-Uk | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.