Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Long-term evaluation and feasibility study of the insulated screw electrode for ECoG recording

Authors
Choi, HoseokLee, SehoLee, JeyeonMin, KyeongranLim, SeokbeenPark, JinsickAhn, Kyoung-haKim, In YoungLee, Kyoung-MinJang, Dong Pyo
Issue Date
Oct-2018
Publisher
ELSEVIER
Keywords
Electrocorticogram; Epidural ECoG; Screw ECoG; Insulation
Citation
JOURNAL OF NEUROSCIENCE METHODS, v.308, pp.261 - 268
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF NEUROSCIENCE METHODS
Volume
308
Start Page
261
End Page
268
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/149245
DOI
10.1016/j.jneumeth.2018.06.027
ISSN
0165-0270
Abstract
Background: A screw-shaped electrode can offer a compromise between signal quality and invasiveness. However, the standard screw electrode can be vulnerable to electrical noise while directly contact with the skull or skin, and the feasibility and stability for chronic implantation in primate have not been fully evaluated. New Method: We designed a novel screw electrocorticogram (ECoG) electrode composed of three parts: recording electrode, insulator, and nut. The recording electrode was made of titanium with high biocompatibility and high electrical conductivity. Zirconia is used for insulator and nut to prevent electrical noise. Result In computer simulations, the screw ECoG with insulator showed a significantly higher performance in signal acquisition compared to the condition without insulator. In a non-human primate, using screw ECoG, clear visual-evoked potential (VEP) waveforms were obtained, VEP components were reliably maintained, and the electrode's impedance was stable during the whole evaluation period. Moreover, it showed higher SNR and wider frequency band compared to the electroencephalogram (EEG). We also observed the screw ECoG has a higher sensitivity that captures different responses on various stimuli than the EEG. Comparison: The screw ECoG showed reliable electrical characteristic and biocompatibility for three months, that shows great promise for chronic implants. These results contrasted with previous reports that general screw electrode was only applicable for acute applications. Conclusion: The suggested electrode can offer whole-brain monitoring with high signal quality and minimal invasiveness. The screw ECoG can be used to provide more in-depth understanding, not only relationship between functional networks and cognitive behavior, but also pathomechanisms in brain diseases.
Files in This Item
Go to Link
Appears in
Collections
서울 의생명공학전문대학원 > 서울 의생명공학전문대학원 > 1. Journal Articles
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, In Young photo

Kim, In Young
COLLEGE OF MEDICINE (DEPARTMENT OF BIOMEDICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE