Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Versatile Carbon Fiber Cloth-supported Au Nanodendrite Sensor for Simultaneous Determination of Cu(II), Pb(II) and Hg(II)

Authors
Dang, Vu HaiYen, Pham Thi HaiGiao, Nguyen QuynhPhong, Pham HongHa, Vu Thi ThuDuy, Pham KhacChung, Hoeil
Issue Date
Oct-2018
Publisher
WILEY-V C H VERLAG GMBH
Keywords
Carbon fiber cloth; gold nanodendrite; simultaneous determination; heavy metals; trace levels
Citation
ELECTROANALYSIS, v.30, no.10, pp.2222 - 2227
Indexed
SCIE
SCOPUS
Journal Title
ELECTROANALYSIS
Volume
30
Number
10
Start Page
2222
End Page
2227
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/149311
DOI
10.1002/elan.201800332
ISSN
1040-0397
Abstract
A carbon fiber cloth (CFC)-supported Au nanodendrite (AuND@CFC) sensor was used to simultaneously measure the concentrations of Pb(II), Cu(II) and Hg(II) in real water samples. The sensor had a large electrochemically active surface area due to the hierarchical nanodendrite structure and the formation of the nanodendrite structure on the CFC was accomplished in just 5 minutes by single-step electrodeposition. After the optimization of important experimental conditions, such as pH and pre-concentration time, the achieved limit of detections (LODs) in the measurements of Pb(II), Cu(II) and Hg(II) were 0.15, 0.07, and 0.13ppb, respectively, which were superior and comparable to those reported in previous studies. The electrochemical responses of each analyte (concentration: 2.0ppb) were not influenced when the concentrations of interferants (Cr(IV), Ni(II), Mn(II), Zn(II), Al(III), Ca(II) and Mg(II)) were even 500-fold greater (1.0ppm); while only the signal of Cu(II) decreased when the Ni(II) concentration were 4.0ppm (2000-fold larger). When eight separately prepared AuND@CFC sensors were used to measure the samples, the relative standard deviations (RSDs) of the peak intensities of these metals were lower than 5.0%, thereby indicating the superior sensor-to-sensor reproducibility. When real river and lake water samples were analyzed, the determined concentrations were similar to those measured with ICP-MS and the recoveries ranged from 93.2%-118.7%. Overall, the proposed sensor is versatile enough to be incorporated into a portable analytical system for on-site detection of Pb(II), Cu(II) and Hg(II) in real field samples.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE