Near-infrared (NIR) spectral features of a target component can be influenced by its particle size as well as the particle sizes of the surrounding components in multi-component samples; therefore, understanding the essence of particle size-induced spectral variation is fundamental for robust quantitative analysis. For systematic investigation, two different types of binary-component samples were prepared. First, in ambroxol/lactose powders, only the particle size of lactose (surrounding filler) was varied, while the particle size of ambroxol (a target component) remained unchanged. Second, in lactose/PE pellets, the particle size of lactose (a target component) was only varied. When measuring ambroxol/lactose powders, the absorbances of both ambroxol and lactose peaks were elevated as the particle size of lactose increased. The larger lactose particle made the photon propagation broader in the sample, so a greater amount of ambroxol was able to interact with NIR photons; this led to an increase in absorbance. In the case of lactose (10 wt%)/PE pellets, the absorbance of lactose oppositely decreased as the lactose particle size increased. Since PE was the dominant component (85-95%) and had a small particle size (7 m), the depth of photon propagation was substantially shallow. In this situation, the larger lactose particles would sometimes not be located within the small sampling volume and/or the photons would only partially interact with the particles; this led to a decrease in the absorbance. For both binary samples, the accuracies for the determination of target concentrations deteriorated as the particle size increased. This was due to the degradation of the measurement reproducibility caused by the increased uncertainty in the photon propagation. Monte Carlo simulation was effective for probing the photon propagation inside samples and supportive to explain the experimental observations.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE