Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of thermal comfort in an office building served by a liquid desiccant-assisted evaporative cooling air-conditioning system

Authors
Cho, Hye-JinJeong, Jae-Weon
Issue Date
Aug-2018
Publisher
ELSEVIER SCIENCE SA
Keywords
Liquid desiccant and evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS); Thermal comfort; Predicted mean vote (PMV); Thermal environment simulation
Citation
ENERGY AND BUILDINGS, v.172, pp.361 - 370
Indexed
SCIE
SCOPUS
Journal Title
ENERGY AND BUILDINGS
Volume
172
Start Page
361
End Page
370
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/149574
DOI
10.1016/j.enbuild.2018.05.016
ISSN
0378-7788
Abstract
The main purpose of this research is to evaluate the thermal-comfort environment in an office building served by a liquid-desiccant and indirect-and-direct evaporative-cooler-assisted 100% outdoor-air system (LD-IDECOAS). This research presents a method for evaluating the thermal environment via a series of energy simulations using the TRNSYS 17 program, integrated with an engineering equation-solver (EES) program. The supply air (SA) temperature is estimated according to the LD-IDECOAS seasonal operation modes proposed in previous research The indoor-air conditions are estimated under the assumption that the relative humidity of room air was maintained at the set values by auxiliary humidification systems. Then, the predicted mean vote (PMV) values are estimated using the given indoor environment conditions. In this paper, the indoor-air conditions and PMV values for each LD-IDECOAS operation mode are represented. A detailed analysis of the impact of the indoor-air conditions on the PMV is provided in this paper. Furthermore, the simulation results for LD-IDECOAS were compared with those for a conventional variable-air-volume (VAV) system to evaluate the thermal environment in a building served by LD-IDECOAS. The PMV values with LD-IDECOAS showed that the thermal environment in a conditioned space is generally in compliance with ASHRAE Standard 55. Consequently, it is concluded that using LD-IDECOAS in an office building can produce energy savings with an acceptable level of thermal comfort.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE