Comparison of Dehumidification Performance of A Single and Two Stage Dehumidifiers In a Liquid Desiccant-Assisted Dedicated Outdoor Air System
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Joon-Young | - |
| dc.contributor.author | Jeong, Jae Weon | - |
| dc.date.accessioned | 2022-07-11T17:12:46Z | - |
| dc.date.available | 2022-07-11T17:12:46Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2018-06 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/149789 | - |
| dc.description.abstract | The aim of this study is to investigate the dehumidification performance and energy conservation of a two-stage liquid desiccant dehumidifier and a single-stage dehumidifier. To enhance the dehumidification performance, a cascade liquid desiccant (CLD) system was applied in an outdoor air unit to adjust the target humidity condition of the induced outdoor air. The CLD consists of a two-stage liquid desiccant dehumidifier unit to carry out deep dehumidification of process air. Process air is dehumidified twice by the CLD system to improve the dehumidification performance of process air compared to a single dehumidifier. The single and cascade liquid desiccant systems were integrated with water-side free cooling using cooling towers for desiccant solution cooling. The energy consumption performance of both systems was evaluated through simulation when operating in an office space as a dedicated outdoor air system (DOAS). The thermal load of a model office space was estimated using TRNSYS 17, and the cooling coil load of DOAS was predicted using a commercial equation solver program. The results show that compared to a single dehumidifier system, CLD requires a lower cooling coil load. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | SIY indoor Air Information | - |
| dc.title | Comparison of Dehumidification Performance of A Single and Two Stage Dehumidifiers In a Liquid Desiccant-Assisted Dedicated Outdoor Air System | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Jeong, Jae Weon | - |
| dc.identifier.bibliographicCitation | Proceedings of Roomvent and Ventilation 2018 Track 3, pp.535 - 540 | - |
| dc.relation.isPartOf | Proceedings of Roomvent and Ventilation 2018 Track 3 | - |
| dc.citation.title | Proceedings of Roomvent and Ventilation 2018 Track 3 | - |
| dc.citation.startPage | 535 | - |
| dc.citation.endPage | 540 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 1 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | Liquid desiccant system | - |
| dc.subject.keywordAuthor | Cascade liquid desiccant | - |
| dc.subject.keywordAuthor | Dedicated outdoor air system | - |
| dc.identifier.url | https://www.lyyti.fi/e/?p=s&k=a0E0486b2BC6d8D0F880e96C | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.