Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Concentration determination of inorganic acids that do not absorb near-infrared (NIR) radiation through recognizing perturbed NIR water bands by them and investigation of accuracy dependency on their acidities

Authors
Chang, KyeolShinzawa, HideyukiChung, Hoeil
Issue Date
Jun-2018
Publisher
ELSEVIER
Keywords
Inorganic acids; Etchant solutions; Water perturbation; Near-infrared spectroscopy; Two-dimensional correlation analysis
Citation
MICROCHEMICAL JOURNAL, v.139, pp.443 - 449
Indexed
SCIE
SCOPUS
Journal Title
MICROCHEMICAL JOURNAL
Volume
139
Start Page
443
End Page
449
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/149921
DOI
10.1016/j.microc.2018.03.019
ISSN
0026-265X
Abstract
When near-infrared (NIR) spectroscopy is employed to determine the concentrations of inorganic acids in etch ant solutions, the perturbation of the water bands resulting from the interactions with these acids is the only information available for analysis, since inorganic acids do not directly absorb NIR radiation. The water bands perturbed by dissociated hydronium ions and respective anions of the acids are not highly component specific; therefore, characterization of their different interactions with water is necessary to understand the results of the multivariate quantitative analysis. For this purpose, the variations in the water bands that occurred with the inclusion of HCI, H2SO4, H3PO4, and HNO3 were initially examined with the aid of a two-dimensional (2D) correlation analysis. According to this analysis, components with higher acidity, such as HCI, perturbed the water hydrogen bonding network more strongly. Also, the interactions between each dissociated ionic species and water molecules were somewhat dissimilar. This dissimilarity enabled differentiation between the four acids, although the spectral specificity was not high owing to the absence of direct NIR absorption. The accuracy in the determination of concentrations was better for components with lower pKas, such as HCI and H2SO4, owing to their stronger perturbation of the water bands. When multicomponent samples were measured, the resulting accuracies deteriorated due to the further degradation in component specificity. Acquisition of reproducible spectra and avoidance of model over-fitting are critical for reliable NIR analysis of these types of samples, as the analyte-induced spectral features are broad and rather specificity-insufficient.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE