Impact of an Ultraviolet Reactor on the Improvement of Air Quality Leaving a Direct Evaporative Cooleropen access

Authors
Kim, WonjunDong, Hye-WonPark, JunseokSung, MinkiJeong, Jae-Weon
Issue Date
Apr-2018
Publisher
MDPI
Keywords
direct evaporative cooler; ultraviolet reactor; indoor air quality; microorganism; water sterilization
Citation
Sustainability, v.10, no.4, pp.1 - 16
Indexed
SCIE
SSCI
SCOPUS
Journal Title
Sustainability
Volume
10
Number
4
Start Page
1
End Page
16
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/150270
DOI
10.3390/su10041123
ISSN
2071-1050
Abstract
The purpose of this study is to improve microbial air quality by improving water quality, particularly concerning microbiological aspects, by applying an ultraviolet water purifier system to a direct evaporative cooling (DEC) system. A direct evaporative cooler is an air cooling technique that uses the evaporation of water. Most DECs recirculate water to reduce water use. Evaporative cooling pads and water are biologically contaminated by recirculating water. This contamination can develop into air contamination and cause respiratory illnesses in occupants. It is necessary to use sterilized water in a DEC to prevent respiratory diseases and maintain air quality. In this study, we examine whether improvements in water quality in a DEC affect air quality by dividing experiments into a control group (Control) and a treated group (UV-treated). In the control group, the degree of contamination was measured when a DEC operated for four weeks without ultraviolet water treatment. In UV-treated, the degree of contamination was measured when UV water treatment was applied to a DEC for four weeks. In both Control and UV-treated, microbes were sampled from the water, the evaporative cooling pad surface, and the DEC inlet and outlet air samples in order to compare the levels of contamination. The surface was measured once at four points, and the air was measured four times at two points. A comparison of the two experiments indicated that the degree of microbial contamination of water and air was significantly reduced in the UV-treated group when compared to that in the control group. When the pollution degree of the evaporative cooling pad was compared to the degree of air pollution, it was difficult to obtain a correlation between the two factors, although the results confirmed that the contamination of the evaporative cooling pad caused water pollution. Therefore, it is necessary to operate a water treatment system to maintain the clean air in DECs.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jun Seok photo

Park, Jun Seok
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE