Unsatisfactory clinical outcomes of second-generation mobile bearing floating platform total knee arthroplasty: comparing outcomes with fixed bearing after fiveyears minimum

Authors
Yoon, Jung-RoYang, Jae-Hyuk
Issue Date
Mar-2018
Publisher
SPRINGER
Keywords
Fixed bearing; Ultracongruent insert; Mobile bearing; Floating platform; Navigation; Total knee arthroplasty
Citation
INTERNATIONAL ORTHOPAEDICS, v.42, pp.2583 - 2589
Indexed
SCIE
SCOPUS
Journal Title
INTERNATIONAL ORTHOPAEDICS
Volume
42
Start Page
2583
End Page
2589
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/150491
DOI
10.1007/s00264-018-3886-y
ISSN
0341-2695
Abstract
Background The purpose of this retrospective study was to analyze and compare the clinical and radiologic outcomes of fixed bearing ultracongruent (UC) insert total knee arthroplasty (TKA) and mobile bearing (MB) floating platform TKA using the navigation-assisted gap balancing technique with a minimum follow-up of five years. Methods The study retrospectively enrolled 105 patients who received the UC type fixed bearing insert (group 1) and 95 patients who received the floating platform MB insert (group 2) during the period from August 2009 to June 2012. All surgery was performed using the navigation-assisted gap balancing technique. For strict assessment of gap measurements, the offset-type-force-controlled-spreader-system was used. Radiologic and clinical outcomes were assessed before operation and at the most recent follow-up using the Knee Society Score (KSS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. For statistical analysis, paired sample t tests were used. A p value less than 0.05 was considered significant. Results Although the radiologic alignments were satisfactory for both groups (99/105 [94%] cases were neutral for group 1 and 90/95 [94%] for group 2), the functional and total WOMAC scores were inferior in group 2 (p < 0.05). There were two cases of insert breakage in group 2 that required bearing exchange. The Kaplan-Meier survivorship rates for groups 1 and 2 at 77 months were 100.0 and 97.9%, respectively. Conclusion Second-generation MB floating platform TKA cases did not have satisfactory outcomes. There were two cases of insert breakage, which required bearing exchange. Other patients who underwent surgery with second-generation MB floating platform were encouraged to avoid high knee flexion activities, resulting in lower clinical performance.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 정형외과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yang, Jae Hyuk photo

Yang, Jae Hyuk
서울 의과대학 (서울 정형외과학교실)
Read more

Altmetrics

Total Views & Downloads

BROWSE