Cited 4 time in
Effect of plasma treatment on adhesion strength and moisture absorption characteristics between epoxy molding compound/silicon chip (EMC/chip) interface
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Oh, Gyung-Hwan | - |
| dc.contributor.author | Joo, Sung-Jun | - |
| dc.contributor.author | Jeong, Jae-Woo | - |
| dc.contributor.author | Kim, Hak-Sung | - |
| dc.date.accessioned | 2021-08-02T12:28:25Z | - |
| dc.date.available | 2021-08-02T12:28:25Z | - |
| dc.date.issued | 2019-01 | - |
| dc.identifier.issn | 0026-2714 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/15134 | - |
| dc.description.abstract | Reliability of interface between two dissimilar materials becomes an important issue due to increasing demands of high-density integrated circuits. Most of failures of semiconductor package occur at the interface between two dissimilar materials in high temperature reflow process, thus, adhesion strength under high temperature should be investigated. In this study, an adhesion shear test jig was newly devised to measure the adhesion strength of epoxy molding compound/Si chip (EMC/chip) interface at high temperature (200 degrees C). In order to investigate the effect of plasma treatment on adhesion strength and moisture absorption characteristics, the number of plasma treatments was varied. Also, moisture absorption time was varied to observe the moisture uptake and degradation of adhesion strength with respect to plasma treatment number. Atomic force microscope (AFM) was analyzed to verify the surface roughness of silicon chip, and scanning electron microscopy (SEM) was used to observe cross-sectional fractured morphology after adhesion strength test. From this study, it was found that the plasma treatments affect much the adhesion strength and moisture uptake at the interface between the EMC/Chip interface. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier Ltd. | - |
| dc.title | Effect of plasma treatment on adhesion strength and moisture absorption characteristics between epoxy molding compound/silicon chip (EMC/chip) interface | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.microrel.2018.11.004 | - |
| dc.identifier.scopusid | 2-s2.0-85057816163 | - |
| dc.identifier.wosid | 000456760500008 | - |
| dc.identifier.bibliographicCitation | Microelectronics and Reliability, v.92, pp 63 - 72 | - |
| dc.citation.title | Microelectronics and Reliability | - |
| dc.citation.volume | 92 | - |
| dc.citation.startPage | 63 | - |
| dc.citation.endPage | 72 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
| dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
| dc.subject.keywordPlus | SURFACE-ROUGHNESS | - |
| dc.subject.keywordPlus | OXIDATION | - |
| dc.subject.keywordPlus | PACKAGE | - |
| dc.subject.keywordPlus | REFLOW | - |
| dc.subject.keywordAuthor | Semiconductor package | - |
| dc.subject.keywordAuthor | Adhesion strength | - |
| dc.subject.keywordAuthor | Plasma treatment | - |
| dc.subject.keywordAuthor | moisture absorption | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S002627141831076X?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
