Influence of ultrasound contrast agents on spectral Doppler analysis in recipients of liver transplantationopen access

Authors
Cho, Young SeoKim, Kyoung WonJang, Hye YoungKim, Bo HyunLee, JeongjinSong, Gi WonLee, Sung GyuMunkhbaatar, Dagvasumberel
Issue Date
Sep-2017
Publisher
KOREAN ASSOC STUDY LIVER
Keywords
Doppler shift; Liver transplantation; Microbubbles
Citation
CLINICAL AND MOLECULAR HEPATOLOGY, v.23, no.3, pp.224 - 229
Indexed
SCOPUS
KCI
Journal Title
CLINICAL AND MOLECULAR HEPATOLOGY
Volume
23
Number
3
Start Page
224
End Page
229
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151707
DOI
10.3350/cmh.2016.0064
ISSN
2287-2728
Abstract
Background/Aims Clinical validation is required to determine whether Doppler measurements are comparable before and after administering ultrasound contrast agent (USCA). The purpose of this study is to explore whether the use of USCA affects spectral Doppler analysis in recipients of liver transplantation (LT). Methods For this study, 36 patients were examined using Doppler ultrasonography (US) along with a contrast-enhanced US for surveillance of vascular complications after LT. The following spectral Doppler US parameters were measured before and after administration of USCA: peak systolic velocity, end-diastolic velocity, resistive index, and systolic acceleration time of the graft hepatic artery; peak flow velocity of the graft portal vein; and peak flow velocity and venous pulsatility index of the graft hepatic vein. Results The mean peak systolic and end-diastolic velocities of the hepatic artery and the peak flow velocity of the portal and hepatic veins were increased after intravenously administration of the USCA, ranging from 10% to 13%. However, the changes were not statistically significant (P=0.097, 0.103, 0.128, and 0.190, respectively). There were no significant differences in other measured parameters, including the resistive index (P=0.205) and systolic acceleration time (P=0.489) of the hepatic artery and venous pulsatility index (P=0.494) of the hepatic vein. Conclusions The measured velocities of graft hepatic vessels tended to increase after administration of USCA, but without statistical significance. The comparison of serial Doppler parameters with or without injection of USCA is valid during Doppler surveillance in recipients of LT.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Young Seo photo

Cho, Young Seo
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE