Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The effect of ocular biometric factors on the accuracy of various IOL power calculation formulasopen access

Authors
Jeong, JinhoSong, HanLee, Jimmy K.Chuck, Roy S.Kwon, Ji Won
Issue Date
May-2017
Publisher
BIOMED CENTRAL LTD
Keywords
Anterior chamber depth; IOL formula; Ocular biometry
Citation
BMC OPHTHALMOLOGY, v.17, no.1, pp.1 - 7
Indexed
SCIE
SCOPUS
Journal Title
BMC OPHTHALMOLOGY
Volume
17
Number
1
Start Page
1
End Page
7
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/152374
DOI
10.1186/s12886-017-0454-y
ISSN
1471-2415
Abstract
Background: To evaluate how differences in ocular biometry affects the Hoffer Q, Holladay 1, SRK/T, and Haigis intraocular lens power calculation formulae predictions. Methods: This study was performed on 91 eyes of 91 patients who underwent uneventful cataract surgery. Ocular biometry values were measured using the IOL Master 500, and intraocular lens (IOL) power was calculated using the Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. We calculated the expected difference (ED) of each 3rd generation formula from the Haigis formula by subtracting the predicted refraction of the Haigis formula from the predicted refraction of each 3rd generation formula. Post-operative anterior chamber depth (ACD) was measured at 1 month after surgery using the IOL master. We calculated errors of each formula by subtracting predicted from manifest refraction at post-operative 1 month. Correlation analysis was performed between ocular biometry values, formula expectation values, formula errors and absolute formula errors. Results: Multiple regression analysis revealed that preoperative ACD was the only significant factor for ED prediction in all of the 3rd generation formulas. For mean errors, axial length and post-operative 1-month change of ACD (delta ACD) correlated significantly with the errors in all 3rd generation formulas, but not with errors of the Haigis formula. Median absolute error (MedAE) of the formulas were 0.40 D for the Hoffer Q formula, 0.37 D for the Holladay formula, 0.34 D for the SRK/T formula, and 0.41 D for the Haigis formula. The MAE of the formulas were 0.50 ± 0.47 D for the Hoffer Q formula, 0.50 ± 0.50 D for the Holladay formula, 0.47 ± 0.51 D for the SRK/T formula, and 0.50 ± 0.47 D for the Haigis formula. Conclusion: Regarding ED between the third generation and Haigis formulas, preoperative ACD demonstrated the greatest influence. Calculating mean absolute errors of the formulas, all IOL formulas showed excellent and comparable accuracy. Post-operative change (delta) of ACD correlated significantly with errors of third generation formulas according to simulated ACD.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 교육협력지원교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kwon, Ji Won photo

Kwon, Ji Won
COLLEGE OF MEDICINE (DEPARTMENT OF MEDICAL COOPERATION)
Read more

Altmetrics

Total Views & Downloads

BROWSE