A robust method to extract the anterior pelvic plane from CT volume independent of pelvic poseopen access

Authors
Lee, ChanghwanKim, Yee sukKim, Hyung WookKim, Young SooJang, Jongseong
Issue Date
Feb-2017
Publisher
TAYLOR & FRANCIS LTD
Keywords
Anterior pelvic plane; acetabular hip orientation; pelvic coordinate; anatomical landmark
Citation
COMPUTER ASSISTED SURGERY, v.22, no.1, pp.20 - 26
Indexed
SCIE
SCOPUS
Journal Title
COMPUTER ASSISTED SURGERY
Volume
22
Number
1
Start Page
20
End Page
26
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/152930
DOI
10.1080/24699322.2017.1293737
ISSN
2469-9322
Abstract
Purpose: The anterior pelvic plane (APP) is commonly used as a reference plane to assess acetabular orientation. However, conventional methods for determining the APP may not be accurate and are prone to user variability. To overcome these issues, we developed a robust method to accurately extract the APP independent of pelvic pose using three-dimensional pelvic computed tomography (CT). Materials and methods: Twenty-eight studies for suspected nonmusculoskeletal conditions were obtained. The APP was determined by four landmarks that were automatically extracted from user-defined regions of interest (ROIs) with compensation of pelvic pose. The APP defined from these landmarks was quantitatively compared to the APPs determined by an expert and an unskilled. Intraobserver reliability was measured to evaluate the time-interval variability. Finally, we evaluate the robustness of this method to patient posture using an arbitrarily rotated volume. The intraclass correlation coefficients (ICCs) were calculated to determine the interobserver and intraobserver reliabilities. Results: The ICC values for the four landmarks and the APP were similar between the semiautomated method and expert determination (ICC >0.937). The ICC values for intraobserver reliability over time for our method were all 1, demonstrating high reliability. Furthermore, agreement between the parameters determined from the original volume and the rotated volume was nearly perfect. Conclusions: Our method is a useful measurement tool for the APP as it is robust, and the results were similar to an experienced surgeon’s determination. Furthermore, it was independent to the direction of the CT slice and more robust than a measurement by an unskilled.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 신경외과학교실 > 1. Journal Articles
서울 의과대학 > 서울 정형외과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yee suk photo

Kim, Yee suk
COLLEGE OF MEDICINE (DEPARTMENT OF ORTHOPEDIC SURGERY)
Read more

Altmetrics

Total Views & Downloads

BROWSE