Which dialysis unit blood pressure is the most accurate for predicting home blood pressure in patients undergoing hemodialysis?open access

Authors
Yoon, I.-C.Choi, H.-M.OH, DONG JIN
Issue Date
Jan-2017
Publisher
KOREAN ASSOC INTERNAL MEDICINE
Keywords
Renal dialysis; Blood pressure; Hypertension; Home; Hemodialysis units, hospital
Citation
KOREAN JOURNAL OF INTERNAL MEDICINE, v.32, no.1, pp.117 - 124
Indexed
SCIE
SCOPUS
KCI
Journal Title
KOREAN JOURNAL OF INTERNAL MEDICINE
Volume
32
Number
1
Start Page
117
End Page
124
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/153017
DOI
10.3904/kjim.2015.278
ISSN
1226-3303
Abstract
Background/Aims: We investigated which dialysis unit blood pressure (BP) is the most useful for predicting home BP in patients undergoing hemodialysis (HD). Methods: Patients undergoing HD who had been treated > 3 months were included in this study. Exclusion criteria were hospitalized patients with acute illness and changes in dry weight and anti-hypertensive drugs 2 weeks before the study. We used the dialysis unit BP recording data, such as pre-HD, intra-HD, post-HD, mean pre-HD, and post-HD (pre-post-HD), mean pre-HD, intra-HD, and postHD (pre-intra-post-HD) BP. Home BP (the same period of dialysis unit BP) was monitored as a reference method during 2 weeks using the same automatic oscillometric device. Patients were asked to record their BP three times daily (wake up, between noon and 6:00 PM, and at bedtime). Results: Significant differences were detected between home systolic blood pressure (SBP) and pre-HD, post-HD, and intra-HD SBP (p = 0.003, p = 0.001, p = 0.016, respectively). In contrast, no differences were observed between home SBP and pre-intra-post-HD and pre-post-HD SBP (p = 0.235, p = 0.307, respectively). Areas under the receiver operating characteristic curve for pre-intra-post-HD and prepost-HD SBP with 2-week home BP as the reference standard were 0.812 and 0.801, respectively. Conclusions: These results suggest that pre-intra-post-HD and pre-post-HD SBP had similar accuracy for predicting mean 2-week home SBP in HD patients. Therefore, pre-intra-post-HD and pre-post-HD SBP should be useful for predicting home SBP in HD patients if ambulatory or home BP measurements are unavailable.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 교육협력지원교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Dong Jin photo

Oh, Dong Jin
COLLEGE OF MEDICINE (DEPARTMENT OF MEDICAL COOPERATION)
Read more

Altmetrics

Total Views & Downloads

BROWSE