Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Added Value of Contrast-Enhanced Ultrasound on Biopsies of Focal Hepatic Lesions Invisible on Fusion Imaging Guidanceopen access

Authors
Kang, Tae WookLee, Min WooSong, Kyoung DooKim, Mi miKim, Seung SooKim, Seong HyunHa, Sang Yun
Issue Date
Jan-2017
Publisher
대한영상의학회
Keywords
Biopsy; Contrast-enhanced ultrasonography; Fusion imaging; Liver; Sonazoid
Citation
Korean Journal of Radiology, v.18, no.1, pp.152 - 161
Indexed
SCIE
SCOPUS
KCI
Journal Title
Korean Journal of Radiology
Volume
18
Number
1
Start Page
152
End Page
161
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/153025
DOI
10.3348/kjr.2017.18.1.152
ISSN
1229-6929
Abstract
Objective: To assess whether contrast-enhanced ultrasonography (CEUS) with Sonazoid can improve the lesion conspicuity and feasibility of percutaneous biopsies for focal hepatic lesions invisible on fusion imaging of real-time ultrasonography (US) with computed tomography/magnetic resonance images, and evaluate its impact on clinical decision making. Materials and methods: The Institutional Review Board approved this retrospective study. Between June 2013 and January 2015, 711 US-guided percutaneous biopsies were performed for focal hepatic lesions. Biopsies were performed using CEUS for guidance if lesions were invisible on fusion imaging. We retrospectively evaluated the number of target lesions initially invisible on fusion imaging that became visible after applying CEUS, using a 4-point scale. Technical success rates of biopsies were evaluated based on histopathological results. In addition, the occurrence of changes in clinical decision making was assessed. Results: Among 711 patients, 16 patients (2.3%) were included in the study. The median size of target lesions was 1.1 cm (range, 0.5-1.9 cm) in pre-procedural imaging. After CEUS, 15 of 16 (93.8%) focal hepatic lesions were visualized. The conspicuity score was significantly increased after adding CEUS, as compared to that on fusion imaging (p < 0.001). The technical success rate of biopsy was 87.6% (14/16). After biopsy, there were changes in clinical decision making for 11 of 16 patients (68.8%). Conclusion: The addition of CEUS could improve the conspicuity of focal hepatic lesions invisible on fusion imaging. This dual guidance using CEUS and fusion imaging may affect patient management via changes in clinical decision-making.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Mimi photo

Kim, Mimi
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE