Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparing the standards of one metabolic equivalent of task in accurately estimating physical activity energy expenditure based on acceleration

Authors
Kim, DohyunLee, JongshillPark, Hoon KiJang, Dong PyoSong, SoohwaCho, Baek HwanJung, Yoo-SukPark, Rae-WoongJoo, Nam-SeokKim, In Young
Issue Date
2017
Publisher
TAYLOR & FRANCIS LTD
Keywords
Acceleration; accelerometer; metabolic equivalent of task; physical activity energy expenditure; resting metabolic rate
Citation
JOURNAL OF SPORTS SCIENCES, v.35, no.13, pp.1279 - 1286
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF SPORTS SCIENCES
Volume
35
Number
13
Start Page
1279
End Page
1286
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/153247
DOI
10.1080/02640414.2016.1221520
ISSN
0264-0414
Abstract
The purpose of the study is to analyse how the standard of resting metabolic rate (RMR) affects estimation of the metabolic equivalent of task (MET) using an accelerometer. In order to investigate the effect on estimation according to intensity of activity, comparisons were conducted between the 3.5 ml O-2 . kg(-1) . min(-1) and individually measured resting VO2 as the standard of 1 MET. MET was estimated by linear regression equations that were derived through five-fold cross-validation using 2 types of MET values and accelerations; the accuracy of estimation was analysed through cross-validation, Bland and Altman plot, and one-way ANOVA test. There were no significant differences in the RMS error after cross-validation. However, the individual RMR-based estimations had as many as 0.5 METs of mean difference in modified Bland and Altman plots than RMR of 3.5 ml O-2 . kg(-1) min(-1). Finally, the results of an ANOVA test indicated that the individual RMR-based estimations had less significant differences between the reference and estimated values at each intensity of activity. In conclusion, the RMR standard is a factor that affects accurate estimation of METs by acceleration; therefore, RMR requires individual specification when it is used for estimation of METs using an accelerometer.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles
서울 의생명공학전문대학원 > 서울 의생명공학전문대학원 > 1. Journal Articles
서울 의과대학 > 서울 가정의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Dong Pyo photo

Jang, Dong Pyo
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING (서울 생체의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE