The Effect of Optic Disc Center Displacement on Retinal Nerve Fiber Layer Measurement Determined by Spectral Domain Optical Coherence Tomography
- Authors
- Shin, Joong Won; Shin, Yong Un; Uhm, Ki Bang; Sung, Kyung Rim; Kang, Min Ho; Cho, Hee Yoon; Seong, Mincheol
- Issue Date
- Oct-2016
- Publisher
- Public Library of Science
- Citation
- PLoS ONE, v.11, no.10, pp 1 - 16
- Pages
- 16
- Indexed
- SCIE
SCOPUS
- Journal Title
- PLoS ONE
- Volume
- 11
- Number
- 10
- Start Page
- 1
- End Page
- 16
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/153905
- DOI
- 10.1371/journal.pone.0165538
- ISSN
- 1932-6203
1932-6203
- Abstract
- Purpose
To investigate the effect of optic disc center displacement on retinal nerve fiber layer (RNFL) measurement determined by spectral domain optical coherence tomography (SD-OCT).
Methods
The optic disc center was manipulated at 1-pixel intervals in horizontal, vertical, and diagonal directions. According to the manipulated optic disc center location, the RNFL thickness data were resampled: (1) at a 3.46-mm diameter circle; and (2) between a 2.5-mm diameter circle and 5.4-mm square. Error was calculated between the original and resampled RNFL measurements. The tolerable error threshold of the optic disc center displacement was determined by considering test-retest variability of SD-OCT. The unreliable zone was defined as an area with 10% or more variability.
Results
The maximum tolerable error thresholds of optic disc center displacement on the RNFL thickness map were distributed from 0.042 to 0.09 mm in 8 directions. The threshold shape was vertically elongated. Clinically important unreliable zones were located: (1) at superior and inferior region in the vertical displacement; (2) at inferotemporal region in the horizontal displacement, and (3) at superotemporal or inferotemporal region in the diagonal displacement. The unreliable zone pattern and threshold limit varied according to the direction of optic disc displacement.
Conclusions
Optic disc center displacement had a considerable impact on whole RNFL thickness measurements. Understanding the effect of optic disc center displacement could contribute to reliable RNFL measurements.