Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Spatiotemporally Defining Biomolecule Preconcentration by Merging Ion Concentration Polarization

Authors
Kwak, Rho kyunKang, Ji YoonKim, Tae Song
Issue Date
Jan-2016
Publisher
AMER CHEMICAL SOC
Citation
ANALYTICAL CHEMISTRY, v.88, no.1, pp.988 - 996
Indexed
SCIE
SCOPUS
Journal Title
ANALYTICAL CHEMISTRY
Volume
88
Number
1
Start Page
988
End Page
996
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/155272
DOI
10.1021/acs.analchem.5b03855
ISSN
0003-2700
Abstract
The ion concentration polarization (ICP) phenomenon at micronanofluidic interfaces has been extensively utilized to preconcentrate low-abundance biological samples. Although preconcentration by ICP is robust, its multiphysics phenomenon does not permit a clear prediction of the preconcentration conditions and sites. Here, we present a new method for spatiotemporally defining preconcentration, which can generate target-condensed plugs in a very specific region (< 100 mu m) regardless of the operating conditions (time, applied voltage, ionic strength, and pH). In contrast to previous devices that use only ion depletion, this device uses merged ICP zones with opposite polarity, i.e., ion depletion and ion enrichment. In this regard, ICP is initiated between two line-patterned cation exchange membranes. When voltage is applied across two membranes, an ion depletion (enrichment) zone occurs on the anodic (cathodic) side of the membranes. Two ICP zones are then merged and confined between the membranes. Consequently, the preconcentration action is also confined between the membranes. We demonstrate that fluorescent dyes are always preconcentrated at the designated location at all lengths of operating time and at broad voltage (0.5-100 V), ionic strength (I-100 mM KCI), and pH (3.7-10.3) ranges. This device successfully condenses proteins up to 10000-fold in a specific region of the channel (100 X SO X 10 mu m(3)) in 10 min. This Work not only characterizes the unique scientific phenomenon of ICP overlapping but also opens the possibility of integrating ICP preconcentrators into commercial analysis equipment, which requires a known, stationary preconcentration site.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kwak, Rho kyun photo

Kwak, Rho kyun
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE