Design and Verification of 150-krpm PMSM Based on Experiment Results of Prototype
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lim, Myung Seop | - |
| dc.contributor.author | Chai, Seung-Hee | - |
| dc.contributor.author | Yang, Jae-Sik | - |
| dc.contributor.author | Hong, Jung-Pyo | - |
| dc.date.accessioned | 2022-07-15T19:58:48Z | - |
| dc.date.available | 2022-07-15T19:58:48Z | - |
| dc.date.issued | 2015-12 | - |
| dc.identifier.issn | 0278-0046 | - |
| dc.identifier.issn | 1557-9948 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/155708 | - |
| dc.description.abstract | This paper proposes the design process of a 2.62-kW 150-krpm high-speed surface-mounted permanent magnet synchronous motor. To meet the required specifications, the numbers of poles and slots were determined by considering the maximum speed and the rotary stability affected by the vibration of the rotor. In addition, this paper describes not only the appropriate material selection method but also the appropriate geometry design method based on analytic approaches. Furthermore, to precisely evaluate the bearing and windage losses at a high speed, a method that combines the finite-element method and the experiment results of the prototype was used. As a result, an improved motor was designed, which had higher maximum power and speed than the prototype and a lower mass moment of inertia. Finally, tests were conducted to verify the validity of the proposed design process and the effectiveness of the motor. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Electrical and Electronics Engineers | - |
| dc.title | Design and Verification of 150-krpm PMSM Based on Experiment Results of Prototype | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TIE.2015.2409804 | - |
| dc.identifier.scopusid | 2-s2.0-84947549935 | - |
| dc.identifier.wosid | 000365019500052 | - |
| dc.identifier.bibliographicCitation | IEEE Transactions on Industrial Electronics, v.62, no.12, pp 7827 - 7836 | - |
| dc.citation.title | IEEE Transactions on Industrial Electronics | - |
| dc.citation.volume | 62 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 7827 | - |
| dc.citation.endPage | 7836 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Automation & Control Systems | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Automation & Control Systems | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordPlus | EQUIVALENT-CIRCUIT ANALYSIS | - |
| dc.subject.keywordPlus | MAGNET SYNCHRONOUS MOTOR | - |
| dc.subject.keywordPlus | HIGH-SPEED | - |
| dc.subject.keywordPlus | MACHINES | - |
| dc.subject.keywordPlus | STATOR | - |
| dc.subject.keywordAuthor | Copper loss | - |
| dc.subject.keywordAuthor | eddy current loss | - |
| dc.subject.keywordAuthor | highspeed machine | - |
| dc.subject.keywordAuthor | iron loss | - |
| dc.subject.keywordAuthor | mechanical loss | - |
| dc.subject.keywordAuthor | surface-mounted permanent-magnet synchronous motor (SPMSM) | - |
| dc.subject.keywordAuthor | vibration | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/7056520 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.