Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effects of acoustic characteristics of combined construction noise on annoyance

Authors
Lee, Sung ChanHong, Joo YoungJeon, Jin Yong
Issue Date
Oct-2015
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Construction noise; Annoyance; Combined noise; Noise pollution
Citation
BUILDING AND ENVIRONMENT, v.92, pp.657 - 667
Indexed
SCIE
SCOPUS
Journal Title
BUILDING AND ENVIRONMENT
Volume
92
Start Page
657
End Page
667
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/156213
DOI
10.1016/j.buildenv.2015.05.037
ISSN
0360-1323
Abstract
Because the acoustic environments of construction sites include multiple noise sources from various construction machines, it is necessary to consider the influence of combined noise on annoyance. The aim of this study is to examine the effects of the acoustic characteristics of combined construction noise on annoyance. Six construction machines, including machines for foundation work (pile drivers, earth augers, and payloaders) and demolition work (breakers, bulldozers, and excavators) were selected as noise sources in construction sites, and auditory experiments were designed to quantify the annoyance caused by the machines individual and combined noise. The results show that both individual and combined noise correlate well with the equivalent sound level (L-Aeq), but that the annoyance caused by combined noise is significantly higher than the annoyance caused by individual noise when L-Aeq increases over 65 dBA. Among the psychoacoustic measures, loudness is the most important in determining the annoyance caused by individual noise, whereas both loudness and roughness significantly impact the annoyance caused by combined construction noise. Ranges of an optimum stationary-to-mobile machine noise ratio between two construction machine noises are suggested to minimize the annoyance caused by combined noise. Optimum stationary-to-mobile machine noise ratio ranges usually include 0 dBA when reference construction noise levels (e.g., pile driver or breaker) are lower than 60 dBA, whereas the stationary-to-mobile machine noise ratio should be greater than 5 dBA as construction noise levels exceed 65 dBA. These findings provide useful information to establish effective noise management plans for combined noise sources in construction sites.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeon, Jin Yong photo

Jeon, Jin Yong
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE