New approach based on tetrahedral-mesh geometry for accurate 4D Monte Carlo patient-dose calculation

Authors
Han, Min CheolYeom, Yeon SooKim, Chan HyeongKim, SeonghoonSohn, Jason W.
Issue Date
Feb-2015
Publisher
Institute of Physics Publishing
Keywords
4D tetrahedral phantom; 4D Monte Carlo; dose calculation; tetrahedral patient model; deformation vector fields
Citation
Physics in Medicine and Biology, v.60, no.4, pp 1601 - 1612
Pages
12
Indexed
SCI
SCIE
SCOPUS
Journal Title
Physics in Medicine and Biology
Volume
60
Number
4
Start Page
1601
End Page
1612
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/157996
DOI
10.1088/0031-9155/60/4/1601
ISSN
0031-9155
1361-6560
Abstract
In the present study, to achieve accurate 4D Monte Carlo dose calculation in radiation therapy, we devised a new approach that combines (1) modeling of the patient body using tetrahedral-mesh geometry based on the patient's 4D CT data, (2) continuous movement/deformation of the tetrahedral patient model by interpolation of deformation vector fields acquired through deformable image registration, and (3) direct transportation of radiation particles during the movement and deformation of the tetrahedral patient model. The results of our feasibility study show that it is certainly possible to construct 4D patient models (=phantoms) with sufficient accuracy using the tetrahedral-mesh geometry and to directly transport radiation particles during continuous movement and deformation of the tetrahedral patient model. This new approach not only produces more accurate dose distribution in the patient but also replaces the current practice of using multiple 3D voxel phantoms and combining multiple dose distributions after Monte Carlo simulations. For routine clinical application of our new approach, the use of fast automatic segmentation algorithms is a must. In order to achieve, simultaneously, both dose accuracy and computation speed, the number of tetrahedrons for the lungs should be optimized. Although the current computation speed of our new 4D Monte Carlo simulation approach is slow (i.e. similar to 40 times slower than that of the conventional dose accumulation approach), this problem is resolvable by developing, in Geant4, a dedicated navigation class optimized for particle transportation in tetrahedral-mesh geometry.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE