실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices

Other Titles
A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices
Authors
김태중강재식박준석
Issue Date
Oct-2014
Publisher
한국태양에너지학회
Keywords
태양열 취득률(Solar Heat Gain Coefficient; SHGC); 열관류율(U-value); 베네시안 블라인드(Venetian blind); 롤스크린(Roll screen); 냉방에너지(Cooling energy)
Citation
한국태양에너지학회 논문집, v.34, no.5, pp 89 - 99
Pages
11
Indexed
KCI
Journal Title
한국태양에너지학회 논문집
Volume
34
Number
5
Start Page
89
End Page
99
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/158898
DOI
10.7836/kses.2014.34.5.089
ISSN
1598-6411
2508-3562
Abstract
The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient(SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to -45˚, 0˚, and –45˚. For the roll screen, measurements were taken with the roll screen in the closed position. In results, the venetian blind reduced SHGC by 21.2~28.4% at 45˚, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind –45˚, 0˚and 45˚, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jun Seok photo

Park, Jun Seok
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE