전세포 커패시턴스 감지법을 이용한 암 진단 바이오센서A biosensor for cancer diagnosis by detecting a difference in capacitance of whole-cell

Other Titles
A biosensor for cancer diagnosis by detecting a difference in capacitance of whole-cell
Authors
하정연김규범송윤흡
Issue Date
Jun-2014
Publisher
대한전자공학회
Citation
전자공학회논문지, v.37, no.1, pp.1290 - 1292
Indexed
OTHER
Journal Title
전자공학회논문지
Volume
37
Number
1
Start Page
1290
End Page
1292
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159678
ISSN
1016135X
Abstract
This paper presents a biosensor that measures capacitance of whole-cell in electrolytic solution. The sensor was fabricated in CMOS technology and invasive breast cancer cell-line MDA-MB-231 was prepared for experiment. The living cell is a complex structure with different electrical properties, however it can be considered simply as a parallel plate capacitor. The capacitances of cancer cell were measured by LCR meter at 10 kHz and 100 kHz. This characteristic of whole-cell should be applicable as applications such as cancer diagnosis and treatment.