Development of a LC-MS/MS for quantification of venlafaxine in human plasma and application to bioequivalence study in healthy korean subjects
- Authors
- Kang, Hyun-Ku; Kang, Min-A; Kim, Hyun-Jin; Park, Yoo-Sin; Kim, Shin-Hee; Kang, Ju-Seop
- Issue Date
- Jun-2014
- Publisher
- Korean Society Clinical Pharmacology and Therapeutics
- Keywords
- Bioequivalence study; LC-MS/MS; Pharmacokinetics; Venlafaxine
- Citation
- Translational and Clinical Pharmacology, v.22, no.1, pp.35 - 42
- Indexed
- SCOPUS
KCI
- Journal Title
- Translational and Clinical Pharmacology
- Volume
- 22
- Number
- 1
- Start Page
- 35
- End Page
- 42
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159780
- DOI
- 10.12793/tcp.2014.22.1.35
- ISSN
- 2289-0882
- Abstract
- A simple, rapid and selective liquid chromatography coupled with tandem mass spectrometry (LCMS/ MS) is developed and validated for quantification of venlafaxine in human plasma with simple liquid-liquid extraction step consisted of extraction with ether and dichloromethane for 10 min and mixing with 1 M sodium acetate in human plasma using fluoxetine as an internal standard (IS). The analyte are separated using an isocratic mobile phase consisted of acetonitrile and 5 mM ammonium formate (4/3, v/v) on a isocratic YMC hydrosphere C18 (2.0×50.0 mm, 3.0 μm) column and analyzed by MS/MS in the multiple reaction monitoring (MRM) mode using the transitions of respective [M+H]+ ions, m/z 278.2→260.3 and m/z 310.1→148.1 for quantification of venlafaxine and IS, respectively. The standard calibration curves showed good linearity within the range of 1.0-200.0 ng/mL (r2=0.9986, 1/x2 weighting). The lower limit of quantification (LLOQ) was 1.0 ng/mL. The retention times of venlafaxine and IS were 0.6 min and 0.7 min that means the potential for the highthroughput potential of the proposed method. In addition, no significant metabolic compounds were found to interfere with the analysis. Acceptable precision and accuracy were obtained for the concentrations over the standard curve range. The validated method was successfully applied to bioequivalence study after 75-mg of venlafaxine sustained-release (SR) capsule in 24 healthy Korean subjects.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 의과대학 > 서울 약리학교실 > 1. Journal Articles
![qrcode](https://api.qrserver.com/v1/create-qr-code/?size=55x55&data=https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159780)
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.