Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

인체 표면 통신을 위한 TM31 고차 모드 반원-링 인체 부착형 마이크로스트립 패치 안테나 설계Design of a TM31 Higher Order Mode Half Circular-Ring Microstrip Patch Antenna for On-Body Communications

Other Titles
Design of a TM31 Higher Order Mode Half Circular-Ring Microstrip Patch Antenna for On-Body Communications
Authors
탁진필전재성김선우최재훈
Issue Date
May-2014
Publisher
한국전자파학회
Keywords
Circular-Ring Microstrip Patch; On-Body; TM31 Mode; Monopole-Like Radiation Pattern
Citation
한국전자파학회 논문지, v.25, no.5, pp 491 - 503
Pages
13
Indexed
KCI
Journal Title
한국전자파학회 논문지
Volume
25
Number
5
Start Page
491
End Page
503
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159975
DOI
10.5515/KJKIEES.2014.25.5.491
ISSN
1226-3133
Abstract
본 논문에서는 모노폴과 같은 방사특성을 갖고 인체 표면 간 통신을 위한 TM31 고차 모드 반원-링 마이크로스트립 패치 안테나를 제안하였다. 제안된 안테나는 단락 핀을 이용하여 TM31 고차 공진 모드를 형성하였고, 평면형임에도 불구하고 모노폴과 같은 방사특성을 갖는다. 패치안테나의 좁은 대역폭을 확장하기 위해 TM31 모드 C-형 반링 패치를 반원 패치에 인접시켰으며, 소형화를 위해 half mode를 사용하였다. 인체 착용환경을 고려하여 마이크로스트립 라인을 이용하여 급전하였다. 제안된 안테나는 ISM(Industrial, Scientific, and Medical) 2.45 GHz 대역(2.4~2.485 GHz)에서 0.25λ0×0.46λ0×0.025λ0의 크기를 갖고, 2.38~2.49 GHz에서 4.24 %의 10-dB 반사손실 대역폭을 갖는다. 인체의 영향을 고려하기 위해 2/3 근육-등가 반고체형 모의인체를 제작하고, 이를 이용하여 안테나에 미치는 인체의 영향을 분석, 검증하였다. 또한, 실제 인체 상황에서 제안된 안테나를 통해 인체 표면 간 링크의 통신 성능 분석을 위한 실험을 수행하였다.
In this paper, a TM31 higher order mode half circular-ring microstrip antenna with monopole-like radiation characteristic for on-body communication is proposed. By using shorting vias, TM31 resonance mode was excited, while achieving compact low-profile antenna with monopole-like radiation characteristics. To overcome the narrow bandwidth of a patch antenna, a C-shape half ring patch with shorting vias having TM31 mode is closely located around a half circular patch. For size reduction, half mode is adopted. The proposed antenna has the overall dimensions of 0.25 λ0×0.46 λ0×0.025 λ0 at the industrial, scientific, and medical(ISM) 2.45 GHz band(2.4~ 2.485 GHz) and the 10-dB return loss is 4.24 % ranging from 2.38 to 2.49 GHz. To verify body effect, two-thirds muscle equivalent semi solid phantom was fabricated and used to measure the antenna performance. A communication link is analysed to investigate the effect of human-body movements and antenna locations.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 융합전자공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE