Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Influence of void on image quality of industrial SPECT

Authors
Park, Jang GuenJung, Seung-HunKim, Jong BumMoon, JinhoKim, Chan Hyeong
Issue Date
Dec-2013
Publisher
IOP PUBLISHING LTD
Keywords
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Inspection with gamma rays
Citation
JOURNAL OF INSTRUMENTATION, v.8, pp.1 - 12
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF INSTRUMENTATION
Volume
8
Start Page
1
End Page
12
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/161318
DOI
10.1088/1748-0221/8/12/P12011
ISSN
1748-0221
Abstract
Industrial single photon emission computed tomography (SPECT) is a promising technique to determine the dynamic behavior of industrial process media and has been developed in the Korea Atomic Energy Research Institute. The present study evaluated the influence of a void, which is presence in multiphase reactors of industrial process, on the image quality of an industrial SPECT. The results are very encouraging; that is, the performance of the industrial SPECT system is little influenced by the presence of a void, which means that industrial SPECT is an appropriate tool to estimate the dynamic characteristics of the process media in a water-air phase bubble column with a static gas sparger.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE