Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

5-hydroxytryptamine measurement using paired pulse voltammetry

Authors
Kim, Suh YoungOh, Yoon BaeShin, Ho JinKim, Do HyungKim, In YoungBennet, KevinLee, Kendall H.Jang, Dong Pyo
Issue Date
Aug-2013
Publisher
Springer Verlag
Keywords
5-Hydroxytryptamine; Electrochemistry; Fast-scan cyclic voltammetry; Paired pulse voltammetry
Citation
Biomedical Engineering Letters, v.3, no.2, pp.102 - 108
Indexed
SCOPUS
KCI
OTHER
Journal Title
Biomedical Engineering Letters
Volume
3
Number
2
Start Page
102
End Page
108
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/162205
DOI
10.1007/s13534-013-0093-z
ISSN
2093-9868
Abstract
Purpose: Although paired-pulse voltammetry (PPV) has significantly reduced the effects of confounding factors such as pH changes, its appliance has been limited to triangular waveforms. Here, we extend PPV to N-waveform, known to be effective in differentiating serotonin (5-HT) from other analytes. Methods: Unlike previous PPV that employs a triangular binary waveform with a specified time gap between the comprising pulses, this study experiments PPV with Nwaveform. N-waveform, the most conventional waveform for detecting 5-HT, sweeps from 0.2 V to 1.0 V to -1.0 V and back to 0.2 V at a sweep rate of 1000 V/s, while the electrode is held at a holding potential of +0.2 V between the voltammetric pulses. After experimenting with various gap times (2 ms, 10 ms, 30 ms, and 45 ms), N-shape PPV was optimized to the parameter of 100 ms repetition time (2 Hz) and 2 ms gap time that displayed the highest sensitivity. 5-HT measurement was performed with a carbon fiber microelectrode placed in the flow cell. PPV data was collected with the Wireless Instantaneous Neurochemical Concentration Sensing System. Results: At the optimized parameter, the oxidation peak in secondary pulse of N-waveform PPV recorded about 68% of the peak of the primary pulse. In addition, the fitting of peak currents in primary, secondary, and primary-secondary in Nshape PPV in relation to the concentration level between 0.25 μM to 2 μM displayed high reliability (R-squared values = 0.9823, 0.9895, 0.9914, respectively). When 5-HT 3 μM and 0.1 ΔpH is mixed, the 10 nA artifact created by 0.1 ΔpH in P-S voltammogram was almost completely removed while the oxidative peak by 5-HT was detected. Conclusions: These results demonstrate that N-shape PPV will enable more accurate measures of real-time serotonin changes, especially in complex environment.
Files in This Item
Go to Link
Appears in
Collections
서울 의생명공학전문대학원 > 서울 의생명공학전문대학원 > 1. Journal Articles
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Dong Pyo photo

Jang, Dong Pyo
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING (서울 생체의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE